Simultaneous Time Interleaved MultiSlice (STIMS) for Rapid Susceptibility Weighted acquisition
نویسندگان
چکیده
T2* weighted 3D Gradient Echo (GRE) acquisition is the main sequence used for Susceptibility Weighted Imaging (SWI) and Quantitative Susceptibility Mapping (QSM). These applications require a long echo time (TE) to build up phase contrast, requiring a long repetition time (TR), and leading to excessively lengthy scans. The long TE acquisition creates a significant amount of unused time within each TR, which can be utilized for either multi-echo sampling or additional image encoding with the echo-shift technique. The latter leads to significant saving in acquisition time while retaining the desired phase and T2* contrast. In this work, we introduce the Simultaneous Time Interleaved MultiSlice (STIMS) echo-shift technique, which mitigates slab boundary artifacts by interleaving comb-shaped slice groups with Simultaneous MultiSlice (SMS) excitation. This enjoys the same SNR benefit of 3D signal averaging as previously introduced multi-slab version, where each slab group is sub-resolved with kz phase encoding. Further, we combine SMS echo-shift with Compressed Sensing (CS) Wave acceleration, which enhances Wave-CAIPI acquisition/reconstruction with random undersampling and sparsity prior. STIMS and CS-Wave combination thus yields up to 45-fold acceleration over conventional full encoding, allowing a 15sec full-brain acquisition with 1.5 mm isotropic resolution at long TE of 39 ms at 3T. In addition to utilizing empty sequence time due to long TE, STIMS is a general concept that could exploit gaps due to e.g. inversion modules in magnetization-prepared rapid gradient-echo (MPRAGE) and fluid attenuated inversion recovery (FLAIR) sequences.
منابع مشابه
Simultaneous acquisition of image and navigator slices using CAIPIRINHA
Introduction Respiratory organ motion is a complicating factor in many treatments. Especially for dynamic dose delivery such as in tumor therapy, exact knowledge of organ motion and its influence on the dose distribution is crucial. Siebenthal et al [1] recently purposed a novel respiratory correlated MR imaging method that acquires a full 2D sagittal navigator image instead of the commonly use...
متن کاملInterleaved T1- and T2*-weighted Imaging Can Evaluate Dynamic Oxygen Challenge: A Feasibility Study
INTRODUCTION Dynamic oxygen challenge evaluated by nuclear magnetic resonance T1 and T2* relaxation times (DOCENT) is a robust non-invasive prognostic test that reveals tumor hypoxia (1,2)., It accomplishes this by exploiting tissue oxygenation level dependent (TOLD) and blood oxygenation level dependent (BOLD) MRI contrast techniques that assess tumor oxygenation in vivo. Currently, no effecti...
متن کاملSystematic noise compensation for simultaneous multislice acquisition using rosette trajectories (SMART).
Simultaneous multislice acquisition using rosette trajectories (SMART) is a recently introduced functional magnetic resonance imaging pulse sequence that offers high-speed data acquisition by simultaneously exciting several slices. A drawback to its benefit of rapid acquisition is the cumulative effect of the systematic noise present in the off-resonant slices. In this work, a systematic noise ...
متن کاملSimultaneous and interleaved acquisition of NMR signals from different nuclei with a clinical MRI scanner
PURPOSE Modification of a clinical MRI scanner to enable simultaneous or rapid interleaved acquisition of signals from two different nuclei. METHODS A device was developed to modify the local oscillator signal fed to the receive channel(s) of an MRI console. This enables external modification of the frequency at which the receiver is sensitive and rapid switching between different frequencies...
متن کاملThe effects of coil compression on simultaneous multislice and conventional fMRI
PURPOSE: Simultaneous multislice (SMS) imaging is an increasingly popular parallel imaging method for accelerating fMRI, but typically requires array coils with many coils, and therefore much storage space and computation time. Here, we investigate the effects that coil compression can have on functional activation for both SMS and conventional fMRI. Although SMS imaging has been demonstrated u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 155 شماره
صفحات -
تاریخ انتشار 2017