Biaxial elastic material properties of porcine coronary media and adventitia.

نویسندگان

  • Aditya Pandit
  • Xiao Lu
  • Chong Wang
  • Ghassan S Kassab
چکیده

The importance of mechanical stresses and strains has become well recognized in vascular physiology and pathology. To compute the stress and strain on the various components of the vessel wall, we must know the constitutive equations for the different layers of the vessel wall. The objective of the present study is to determine the constitutive equation of the coronary artery treated as a two-layer composite: intima-media and adventitial layers. Twelve hearts were obtained from a local slaughterhouse, and the right coronary artery and left anterior descending artery were dissected free from the myocardium. The vessel wall was initially mechanically tested biaxially (inflation and axial extension) as a whole (intact wall) and subsequently as intima-media or adventitial layer. A Fung-type exponential strain energy function was used to curve fit the experimental data for the intact wall and individual layers for the right coronary artery and left anterior descending artery. Two methods were used for the determination of material constants, including the Marquardt-Levenberg nonlinear least squares method and the genetic algorithm method. Our results show that there were no statistically significant differences in the material constants obtained from the two methods and that either set of elastic constants results in good fit of the data. Furthermore, at an in vivo value of axial stretch ratio, we find that the stiffness is as follows: intima-media > intact > adventitia. These results underscore the composite nature of coronary arteries with different material properties in each layer. The present results are necessary for analysis of coronary artery mechanics and to provide a fundamental understanding of vessel physiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biaxial incremental homeostatic elastic moduli of coronary artery: two-layer model.

The detailed mechanical properties of various layers of the coronary artery are important for understanding the function of the vessel. The present article is focused on the determination of the incremental modulus in different layers and directions in the neighborhood of the in vivo state. The incremental modulus can be defined for any material subjected to a large deformation if small perturb...

متن کامل

Right coronary artery becomes stiffer with increase in elastin and collagen in right ventricular hypertrophy.

Changes in blood flow influence the structure, function, mechanical properties, and remodeling of arteries. The objective of the present study was to investigate the role of increased blood flow on the biaxial incremental elastic moduli of the porcine right coronary artery (RCA) and to determine the microstructural basis for the changes in moduli. We hypothesized that an increase in RCA flow wi...

متن کامل

Finite Difference Method for Biaxial and Uniaxial Buckling of Rectangular Silver Nanoplates Resting on Elastic Foundations in Thermal Environments Based on Surface Stress and Nonlocal Elasticity Theories

In this article, surface stress and nonlocal effects on the biaxial and uniaxial buckling of rectangular silver nanoplates embedded in elastic media are investigated using finite difference method (FDM). The uniform temperature change is utilized to study thermal effect. The surface energy effects are taken into account using the Gurtin-Murdoch’s theory. Using the principle of virtual work, the...

متن کامل

Shear modulus of porcine coronary artery: contributions of media and adventitia.

The epicardial coronary arteries experience significant torsion in the axial direction due to changes in the shape of the heart during the cardiac cycle. The objective of this study was to determine the torsional mechanical properties of the coronary arteries under various circumferential and longitudinal loadings. The coronary artery was treated as a two-layer composite vessel consisting of in...

متن کامل

Biaxial biomechanical properties of self-assembly tissue-engineered blood vessels.

Along with insights into the potential for graft success, knowledge of biomechanical properties of small diameter tissue-engineered blood vessel (TEBV) will enable designers to tailor the vessels' mechanical response to closer resemble that of native tissue. Composed of two layers that closely mimic the native media and adventitia, a tissue-engineered vascular adventitia (TEVA) is wrapped aroun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 288 6  شماره 

صفحات  -

تاریخ انتشار 2005