Central and peripheral blood flow during exercise with a continuous-flow left ventricular assist device: constant versus increasing pump speed: a pilot study.

نویسندگان

  • Patrice Brassard
  • Annette S Jensen
  • Nikolai Nordsborg
  • Finn Gustafsson
  • Jacob E Møller
  • Christian Hassager
  • Søren Boesgaard
  • Peter Bo Hansen
  • Peter Skov Olsen
  • Kåre Sander
  • Niels H Secher
  • Per Lav Madsen
چکیده

BACKGROUND End-stage heart failure is associated with impaired cardiac output (CO) and organ blood flow. We determined whether CO and peripheral perfusion are maintained during exercise in patients with an axial-flow left ventricular assist device (LVAD) and whether an increase in LVAD pump speed with work rate would increase organ blood flow. METHODS AND RESULTS Invasively determined CO and leg blood flow and Doppler-determined cerebral perfusion were measured during 2 incremental cycle exercise tests on the same day in 8 patients provided with a HeartMate II LVAD. In random order, patients exercised both with a constant (≈9775 rpm) and with an increasing pump speed (+400 rpm per exercise stage). At 60 W, the elevation in CO was more pronounced with increased pump speed (8.7±0.6 versus 8.1±1.1 L · min(-1); mean±SD; P=0.05), but at maximal exercise increases in CO (from 7.0±0.9 to 13.6±2.5 L · min(-1); P<0.01) and leg blood flow [0.7 (0.5 to 0.8) to 4.4 (3.9 to 4.8) L · min(-1) per leg; median (range); P<0.001] were similar with both pumping modes. Normally, middle cerebral artery mean flow velocity increases from ≈50 to ≈65 cm · s(-1) during exercise, but in LVAD patients with a constant pump speed it was low at rest (39±14 cm · s(-1)) and remained unchanged during exercise, whereas in patients with increasing pump speed, it increased by 5.2±2.8 cm · s(-1) at 60 W (P<0.01). CONCLUSIONS With maximal exercise, the axial-flow LVAD supports near-normal increments in cardiac output and leg perfusion, but cerebral perfusion is poor. Increased pump speed augments cerebral perfusion during exercise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices.

BACKGROUND Continuous-flow rotary pumps with axial design are increasingly used for left ventricular assist support. The efficacy of this design compared with pulsatile, volume displacement pumps, with respect to characteristics of left ventricular unloading, and exercise performance remains largely unstudied. METHODS AND RESULTS Thirty-four patients undergoing implantation with a pulsatile, ...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System

Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBake...

متن کامل

Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device

The aim of the investigation is to develop a control method of a rotary blood pump (RBP) to solve the following problems: estimation of the pump flow rate, achievement and maintaining of the desired flow level through the continuous adjustment of pump speed and prevention of adverse effects on the cardiovascular system. Results. Functional chart of RBP control consists of several units: a unit ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 2011