An in vitro investigation of peak insertion torque values of six commercially available mini-implants.

نویسندگان

  • C Z Y Whang
  • D Bister
  • M Sherriff
چکیده

This study compared peak insertion torque values of six commercially available self-drilling mini-implants [Mini Spider® screw (1.5 × 8 mm), Infinitas® (1.5 × 9 mm), Vector TAS® (1.4 × 8 mm), Dual Top® (1.6 × 8 mm), Tomas Pin® (1.6 × 8 mm), and Ortho-Easy® (1.7 × 6, 8, and 10 mm)]. Twenty implants each were drilled into acrylic rods at a speed of 8 rpm using a motorized torque measurement stand, and the values were recorded in Newton centimetres (Ncm). A further 20 Ortho-Easy® implants with a length of 6 and 10 mm were tested at 8 rpm; 20 implants of 6 mm length were also tested at 4 rpm. Kaplan-Meier estimates of the peak torque values were compared using the log-rank test with multiple comparisons evaluated by Sidak's test. There were significant differences in the maximum torque values for different mini-implants with the same length. The Mini Spider® screw and Infinitas® showed the lowest average torque values (6.5 and 12.4 Ncm) compared with Vector TAS®, Dual ToP®, Tomas Pin®, and Ortho-Easy® (30.9, 29.4, 25.4, and 24.8 Ncm, respectively). There was no correlation between the diameter of the implants and torque values. The Tomas Pin® showed the largest standard deviation (7.7 Ncm) and the Dual Top® implant the smallest (0.6 Ncm). Different insertion speeds did not result in significant differences in peak torque values but the 6 mm mini-implants showed significantly higher torque values than the 8 and 10 mm implants. Using a 'torque limiting' screwdriver or pre-drilling cortical bone to reduce insertion, torque appears justified for some of the tested implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rotational resistance of surface-treated mini-implants.

OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were...

متن کامل

Insertion Torques of Self-Drilling Mini-Implants in Simulated Mandibular Bone: Assessment of Potential for Implant Fracture.

PURPOSE Fracture of orthodontic mini-implants during insertion is a limiting factor for their clinical success. The purpose of this study was to determine the fracture potential of commonly used self-drilling orthodontic mini-implants when placed into simulated thick, dense mandibular bone. MATERIALS AND METHODS Six mini-implant systems were assessed for the potential for fracture (Aarhus, Me...

متن کامل

Geometrical design characteristics of orthodontic mini-implants predicting maximum insertion torque

OBJECTIVE To determine the unique contribution of geometrical design characteristics of orthodontic mini-implants on maximum insertion torque while controlling for the influence of cortical bone thickness. METHODS Total number of 100 cylindrical orthodontic mini-implants was used. Geometrical design characteristics of ten specimens of ten types of cylindrical self-drilling orthodontic mini-im...

متن کامل

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

متن کامل

بررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی

Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2011