Evaluation of left ventricular ejection fraction using through-time radial GRAPPA

نویسندگان

  • Gunhild Aandal
  • Vidya Nadig
  • Victoria Yeh
  • Prabhakar Rajiah
  • Trevor Jenkins
  • Abdus Sattar
  • Mark Griswold
  • Vikas Gulani
  • Robert C Gilkeson
  • Nicole Seiberlich
چکیده

BACKGROUND The determination of left ventricular ejection fraction using cardiovascular magnetic resonance (CMR) requires a steady cardiac rhythm for electrocardiogram (ECG) gating and multiple breathholds to minimize respiratory motion artifacts, which often leads to scan times of several minutes. The need for gating and breathholding can be eliminated by employing real-time CMR methods such as through-time radial GRAPPA. The aim of this study is to compare left ventricular cardiac functional parameters obtained using current gold-standard breathhold ECG-gated functional scans with non-gated free-breathing real-time imaging using radial GRAPPA, and to determine whether scan time or the occurrence of artifacts are reduced when using this real-time approach. METHODS 63 patients were scanned on a 1.5T CMR scanner using both the standard cardiac functional examination with gating and breathholding and the real-time method. Total scan durations were noted. Through-time radial GRAPPA was employed to reconstruct images from the highly accelerated real-time data. The blood volume in the left ventricle was assessed to determine the end systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) for both methods, and images were rated for the presence of artifacts and quality of specific image features by two cardiac readers. Linear regression analysis, Bland-Altman plots and two-sided t-tests were performed to compare the quantitative parameters. A two-sample t-test was performed to compare the scan durations, and a two-sample test of proportion was used to analyze the presence of artifacts. For the reviewers´ ratings the Wilcoxon test for the equality of the scores' distributions was employed. RESULTS The differences in EF, EDV, and ESV between the gold-standard and real-time methods were not statistically significant (p-values of 0.77, 0.82, and 0.97, respectively). Additionally, the scan time was significantly shorter for the real-time data collection (p<0.001) and fewer artifacts were reported in the real-time images (p<0.01). In the qualitative image analysis, reviewers marginally preferred the standard images although some features including cardiac motion were equivalently rated. CONCLUSION Real-time functional CMR with through-time radial GRAPPA performed without ECG-gating under free-breathing can be considered as an alternative to gold-standard breathhold cine imaging for the evaluation of ejection fraction in patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of left ventricular ejection fraction using through-time radial GRAPPA for real-time imaging

Background Cardiac MRI requires a steady cardiac rhythm for ECGgating, and multiple breath-holds to minimize respiratory artifacts. By employing a non-Cartesian parallel imaging in form of through-time radial GRAPPA [1], accelerated imaging can be performed with temporal resolutions of < 50 ms, obviating the need for gating or breath-holding. breath-holding. We tested the hypothesis that volume...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

The effect of eight weeks of moderate-intensity endurance training on myocardial capillary density, ejection fraction and left ventricular shortening fraction in male rats with myocardial infarction

Background and objective: Vascular obstruction and impaired blood flow and oxygen delivery cause a myocardial infarction and limit a personchr('39')s function. Therefore, finding a way to create new arteries and replace blocked arteries has always been of interest to researchers, including exercise physiologists. Therefore, this study was conducted to evaluate the effect of eight weeks of moder...

متن کامل

Evaluation of Cardiac Function in Patients with Thalassemia Intermedia

Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...

متن کامل

Evaluation of heart disease in patients with beta-thalessemia major referred to Shahid Madanni Hospital in Khorram Abad in 2003

Background: Patients with beta-thalessemia major present with severe anemia and need continous transfusion therapy. An important complication of beta-thalessemia major is iron deposition in cardiac tissue, resulting in fibrosis and dysfunction. Cardiac involvement is the major cause of death in beta-thalessemia major. The purpose of this study was to assess cardiac disease patients with bet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2014