Clinical comparison of an agar slide blood culture bottle with tryptic soy broth and a conventional blood culture bottle with supplemented peptone broth.
نویسندگان
چکیده
The Roche Septi-Chek biphasic blood culture system with tryptic soy broth was compared with a conventional blood culture bottle with supplemented peptone broth in 6,956 paired blood cultures from adult patients. Both systems were inoculated with equal volumes of blood (5 ml) and incubated aerobically (vented) for 2 weeks. More clinically important bacteria and fungi, including Staphylococcus aureus, S. epidermidis, Escherichia coli and other Enterobacteriaceae, Pseudomonas aeruginosa, and Candida albicans and C. tropicalis were recovered from the biphasic system (P less than 0.001). In contrast, more clinically important anaerobic bacteria (P less than 0.001) and Gardnerella vaginalis (P less than 0.05) were recovered in conventional supplemented peptone broth. Staphylococci (P less than 0.01), Enterobacteriaceae other than E. coli (P less than 0.05), and fungi (P less than 0.001) were detected 1 or more days earlier in the biphasic system, whereas streptococci (P less than 0.001) were detected earlier in the conventional bottle. The overall superiority of the agar slide blood culture system compared with conventional blood culture bottles was confirmed by this evaluation. For optimal detection of anaerobic bacteremia, however, the agar slide bottle should be paired with an anaerobic bottle.
منابع مشابه
Clinical laboratory comparison of a slide blood culture system with a conventional broth system.
The recovery of bacteria and fungi from blood cultures was compared in conventional tryptic soy broth (TSB) bottles and in TSB bottles with an agarcoated slide attachment. A total of 2,662 sets of blood cultures, including 413 that were positive (15.5%), were evaluated. Significantly more gram-positive and gram-negative bacteria were recovered in the slide culture bottles than in conventional b...
متن کاملComparison of the Roche Septi-Chek blood culture bottle with a brain heart infusion biphasic medium bottle and with a tryptic soy broth bottle.
In a comparison of 1,368 positive blood cultures, a vented Roche Septi-Chek (V-RSC) blood culture bottle was superior to an unvented tryptic soy broth-containing bottle (Difco) for the recovery of all aerobic and facultatively anaerobic microorganisms. Anaerobic bacteria were recovered more frequently and earlier in the unvented tryptic soy broth-containing bottle. A separate comparison of 529 ...
متن کاملControlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.
Blood culture bottles that accept up to 10 ml of blood have recently been introduced for the BACTEC nonradiometric blood culture system. The new formulation, designated BACTEC Plus, contains 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. In a collaborative study conducted at three university hospitals, we evaluated the BACTEC Plus 26 (BP26) aerobic bottle and ...
متن کاملComparison of three blood culture media with tryptic soy broth.
Four consecutive studies comparing commercially prepared bottles that contained brain heart infusion, brucella (vented and unvented), and Trypticase soy broths with Tryptic soy broth failed to demonstrate significant differences in rates of isolation of organisms from blood. Statistically significant differences between bottles were limited to the average times required to detect growth of viri...
متن کاملPerformance characteristics of a commercially prepared biphasic blood culture bottle.
A biphasic blood culture bottle (BiPB: GIBCO Laboratories, North Andover, Mass.) with an architectural design that physically separates the agar slant from the broth was compared with a conventional vented monophasic bottle (MPB-A) for use in the routine culture of blood. Both bottles contained tryptic soy broth. Tryptic soy agar was used for the BiPB slant. A third unvented bottle (MPB-N) with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 21 5 شماره
صفحات -
تاریخ انتشار 1985