Assessment of corneal biomechanical properties in normal tension glaucoma and comparison with open-angle glaucoma, ocular hypertension, and normal eyes.

نویسندگان

  • Alice Grise-Dulac
  • Alain Saad
  • Olivia Abitbol
  • Jean-Luc Febbraro
  • Elodie Azan
  • Christine Moulin-Tyrode
  • Damien Gatinel
چکیده

PURPOSE To assess the biomechanical properties of corneas in patients with normal tension glaucoma (NTG) and to compare them with those of patients with primary open-angle glaucoma (POAG), ocular hypertension (OHT), and normal controls (N). METHODS Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann intraocular pressure (IOPg), and corneal compensated IOP (IOPcc) were obtained using an ocular response analyzer for 28 eyes in 14 patients with NTG, 75 eyes in 38 patients with chronic POAG, 53 eyes of 27 patients with OHT, and 44 eyes of 22 N controls. IOP using Goldmann applanation tonometry (IOPGA) and ultrasonic central corneal thickness (CCT) were also measured for each eye. Analysis of variance test was used for statistical analysis. RESULTS CH was significantly lower in the NTG group (9.88±2.02 mm Hg) compared with the N group (11.05±1.53 mm Hg; P<0.01). CRF was significantly lower in the NTG group (9.5±1.89 mm Hg) compared with the POAG group (11.15±2.35 mm Hg; P<0.01) and to the N group (11.00±1.75 mm Hg; P<0.01). CCT was not considered significantly different between the 4 groups. However, IOPcc was found to be significantly lower in NTG group compared with the POAG group and OHT group (P<0.001). CONCLUSION NTG was associated with significantly lower CRF than chronic POAG and N patients. CH and CRF could be a useful tool in early diagnosis of NTG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The importance of assessing corneal biomechanical properties in glaucoma patients care - a review.

Purpose: to familiarize the public with the role of corneal biomechanics in glaucoma patient management. Methods: Ocular Response Analyzer (ORA) is the only device that measures in vivo corneal biomechanics. Recent studies regarding "corneal biomechanics and glaucoma" were reviewed and the obtained data were compared in order to present a better understanding of the corneal biomechanical proper...

متن کامل

Central corneal thickness measurements in patients with normal tension glaucoma, primary open angle glaucoma, pseudoexfoliation glaucoma, or ocular hypertension.

BACKGROUND/AIMS Recent studies have revealed patients with ocular hypertension to have thicker than normal central corneas and those with normal tension glaucoma to have thinner than normal ones, as determined by ultrasonic pachymetry. Since corneal thickness measurements and applanation tonometric estimates of intraocular pressure (IOP) correlate positively, monitoring of the former parameter ...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

[Importance of central corneal thickness when studying ocular hypertensive eyes, glaucoma suspects and preperimetric glaucomatous eyes].

PURPOSE To compare the central corneal thickness, measured with an ultrasound pachymeter, in normal subjects, those with ocular hypertension, glaucoma suspects and patients with preperimetric glaucoma. METHODS 61 normal eyes (control group), 131 eyes with ocular hypertension, 62 glaucoma suspects (optic nerve head morphology compatible with glaucoma) and 36 patients with preperimetric glaucom...

متن کامل

Central corneal thickness of normal tension glaucoma patients in Japan.

PURPOSE To compare central corneal thickness (CCT) of patients with normal tension glaucoma (NTG) with that of age-matched normal subjects, patients with open-angle glaucoma (POAG) and ocular hypertension (OH) subjects in Japan. METHODS Central corneal thickness was measured in 79 NTG, 61 POAG, 73 OH, and 50 normal subjects with an ultrasonic pachymeter. One eye for 1 subject randomly selecte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of glaucoma

دوره 21 7  شماره 

صفحات  -

تاریخ انتشار 2012