High blood pressure during breath-hold diving is not a physiological absurdity.

نویسندگان

  • Massimo Ferrigno
  • Claes E G Lundgren
چکیده

TO THE EDITOR: In a 2009 article, Sieber et al. (4), having found “normal” blood pressures (BPs) using a sphygmomanometric method in subjects performing breath-hold dives to 10 m of depth, suggested that the very high BPs we recorded invasively in two healthy expert breath-hold divers diving to 6 ATA (50 m) in our pressure chamber (2) were artifacts caused by our recording system. They also argued that our “alarming values” of BP are incompatible with normal physiology, despite the fact that BPs of the same magnitude have also been recorded in healthy breath-holders in other laboratories (1, 3). Sieber et al. (4) suggest that the reference chamber of our pressure transducer (model CDXIII, Cobe Cardiovascular Labs, Arvada, CO) did not keep pace with the ambient pressure changes during the dives. Surprisingly, they disregard the following information in the METHODS of our paper (2): “The system had been tested in separate (unmanned) compressions for absence of pressure and temperature biases.” Seiber et al. (4) attempted to verify their hypothesis of a technical bias in our recording system but, while trying to reproduce our recording situation, employed a different type of transducer and experimental set-up. Thus the pressure bias they recorded has no apparent bearing on our experimental methodology. This conclusion is strengthened by recently repeated tests in our laboratory using the original pressure profile and transducer actually employed in the original study (2) as well as an identical, unused transducer; tests that again showed no relevant artifacts. Thus we feel confident that our published measurements of BP in the simulated deep breath-hold dives (2) are free of methodological errors. Scrutinizing our results, Seiber et al. (4) chose to analyze only the BP recording in Fig. 5B, ignoring the one in Fig. 5A, which contradicts their arguments. They gave no consideration to the possibility that the BP reduction during the “ear-clearing” stops in Fig. 5B might have a physiological explanation. It is well known that the Valsalva maneuver, often used for ear clearing, can impede venous return and reduce cardiac output and blood pressure. Looking at Fig. 5A the same way as these authors analyzed Fig. 5B yields a very different outcome: during the first compression stop, the BP increased to the highest level in the entire dive (292/168 mmHg); during the second stop, the BP remained in the 250/150 mmHg range. The absence of drops in BP would be expected if the diver achieved ear clearing by swallowing or using the Frenzel maneuver, neither of which increases intrathoracic pressure. The reduction in BP during the bottom stay and ascent in diver RM (Fig. 5B) agrees perfectly with the bradycardia-based halving of cardiac output during these dive phases (Fig. 4, 25° in Ref. 2). Different diving conditions in the Seiber et al. study and ours may explain differences in outcome. The divers in the Seiber et al. study wore wetsuits in 26°C water. Thus their skin temperatures were considerably higher than in the divers in our study who were unprotected against the temperature of 25°. Cool water is likely to enhance the circulatory diving response. Furthermore, in the Seiber et al. study, the divers, sitting still at 10 m for the 50to 60-s-long BP measurement procedure were, during that time, probably in a relatively stable circulatory state. By contrast, except for two 5to 6-s interruptions of descent and 16 s at the bottom, the divers of our study underwent dynamic depth changes of between 1.2 and 0.8 m/s. Thus they experienced continuous changes in physiological stressors. In sensory physiology, dynamically changing stimulation is known to be often more effective than static stimulation. It might be that the shrinking, respectively, expanding lung/chest volume during compression/decompression acted particularly forcefully on the mechanism, so far unexplained, that causes the diving response to be more pronounced at low lung volumes than at large. In conclusion, we hold that our observations during actual diving conditions demonstrate genuine physiological and quantitatively correct BP increases. Clearly, the frequency in the general breath-hold diving population of the reactions we have observed cannot be determined from our measurements in two blood-related divers. However, since 4/10 subjects in Seiber et al.’s study had diastolic BPs reaching 100 mmHg or more when diving, one may hypothesize that those subjects, if exposed to dynamically changing depth, would have developed even more impressive BP changes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diving Physiology of Marine Vertebrates

Air-breathing marine vertebrates that dive to find food deal with two fundamental problems, the effects of pressure at depth, and the need to actively forage while breathholding. Adaptations to diving can be divided into two categories, those that are associated with adaptations to pressure, and those associated with breath-hold diving. Adaptations to pressure have to deal with the mechanical e...

متن کامل

Sports-related lung injury during breath-hold diving.

The number of people practising recreational breath-hold diving is constantly growing, thereby increasing the need for knowledge of the acute and chronic effects such a sport could have on the health of participants. Breath-hold diving is potentially dangerous, mainly because of associated extreme environmental factors such as increased hydrostatic pressure, hypoxia, hypercapnia, hypothermia an...

متن کامل

The physiology and pathophysiology of human breath-hold diving.

This is a brief overview of physiological reactions, limitations, and pathophysiological mechanisms associated with human breath-hold diving. Breath-hold duration and ability to withstand compression at depth are the two main challenges that have been overcome to an amazing degree as evidenced by the current world records in breath-hold duration at 10:12 min and depth of 214 m. The quest for ev...

متن کامل

The diving physiology of bottlenose dolphins (Tursiops truncatus). I. Balancing the demands of exercise for energy conservation at depth.

During diving, marine mammals must rely on the efficient utilization of a limited oxygen reserve sequestered in the lungs, blood and muscles. To determine the effects of exercise and apnea on the use of these reserves, we examined the physiological responses of adult bottlenose dolphins (Tursiops truncatus) trained to breath-hold on the water surface or to dive to submerged targets at depths be...

متن کامل

Diving mammals.

The ability of diving mammals to forage at depth on a breath hold of air is dependent on gas exchange, both in the lung and in peripheral tissues. Anatomical and physiological adaptations in the respiratory system, cardiovascular system, blood and peripheral tissues contribute to the remarkable breath-hold capacities of these animals. The end results of these adaptations include efficient venti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 109 5  شماره 

صفحات  -

تاریخ انتشار 2010