Fetal magnetocardiography measurements with an array of microfabricated optically pumped magnetometers.

نویسندگان

  • Orang Alem
  • Tilmann H Sander
  • Rahul Mhaskar
  • John LeBlanc
  • Hari Eswaran
  • Uwe Steinhoff
  • Yoshio Okada
  • John Kitching
  • Lutz Trahms
  • Svenja Knappe
چکیده

Following the rapid progress in the development of optically pumped magnetometer (OPM) technology for the measurement of magnetic fields in the femtotesla range, a successful assembly of individual sensors into an array of nearly identical sensors is within reach. Here, 25 microfabricated OPMs with footprints of 1 cm(3) were assembled into a conformal array. The individual sensors were inserted into three flexible belt-shaped holders and connected to their respective light sources and electronics, which reside outside a magnetically shielded room, through long optical and electrical cables. With this setup the fetal magnetocardiogram of a pregnant woman was measured by placing two sensor belts over her abdomen and one belt over her chest. The fetal magnetocardiogram recorded over the abdomen is usually dominated by contributions from the maternal magnetocardiogram, since the maternal heart generates a much stronger signal than the fetal heart. Therefore, signal processing methods have to be applied to obtain the pure fetal magnetocardiogram: orthogonal projection and independent component analysis. The resulting spatial distributions of fetal cardiac activity are in good agreement with each other. In a further exemplary step, the fetal heart rate was extracted from the fetal magnetocardiogram. Its variability suggests fetal activity. We conclude that microfabricated optically pumped magnetometers operating at room temperature are capable of complementing or in the future even replacing superconducting sensors for fetal magnetocardiography measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optically pumped alkali magnetometers for biomedical applications

20 Optically pumped atomic magnetometers measure the Larmor frequency νL at which the bulk magnetization of a spin-polarized alkali metal vapour in a glass cell precesses around the field of interest B0. !e precession frequency is related to the modulus of the magnetic field by νL=(γ/2π)|B0|, where γ/2π≈3.5Hz/nT for 133Cs, so that the magnetic field measurement consists in a frequency measureme...

متن کامل

Measurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers

Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...

متن کامل

High Sample Rate Optically Pumped Helium Magnetometer

Optically pumped helium magnetometers are important instruments whichhave many applications in military, mass spectroscopy and space applications. In thispaper, the working principles of helium magnetometers have been explained. There isalso an introduction of a new method for finding the resonant frequency, which hasadvantages to the typical method such as more sample r...

متن کامل

Magnetic field imaging with microfabricated optically-pumped magnetometers.

A multichannel imaging system is presented, consisting of 25 microfabricated optically-pumped magnetometers. The sensor probes have a footprint of less than 1 cm2 and a sensitive volume of 1.5 mm × 1.5 mm × 1.5 mm and connect to a control unit through optical fibers of length 5 m. Operating at very low ambient magnetic fields, the sensor array has an average magnetic sensitivity of 2...

متن کامل

Optical magnetometer array for fetal magnetocardiography.

We describe an array of spin-exchange-relaxation-free optical magnetometers designed for detection of fetal magnetocardiography (fMCG). The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected by a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 60 12  شماره 

صفحات  -

تاریخ انتشار 2015