Dual lag screw cephalomedullary nail versus the classic sliding hip screw for the stabilization of intertrochanteric fractures. A prospective randomized study

نویسندگان

  • G. Kouvidis
  • V. I. Sakellariou
  • A. F. Mavrogenis
  • J. Stavrakakis
  • D. Kampas
  • J. Galanakis
  • P. J. Papagelopoulos
  • P. Katonis
چکیده

This study is a randomized prospective study comparing two fracture fixation implants, the extramedullary sliding hip screw (SHS) and the dual lag screw cephalomedullary nail, in the treatment of intertrochanteric femoral fractures in the elderly. One hundred and sixty-five patients with low-energy intertrochanteric fractures, classified as AO/OTA 31A, were prospectively included during a 2-year period (2005-2006). Patients were randomized into two groups: group A included 79 hip fractures managed with sliding hip screws and group B included 86 fractures treated with cephalomedullary nails. Delay to surgery, duration of surgery, time of fluoroscopy, total hospital stay, implant-related complications, transfusion requirements, re-operation details, functional recovery, and mortality were recorded. The mean follow-up was 36 months (24-56 months). The mean surgical time was statistically significantly shorter and fluoroscopy time longer for the group B. No intraoperative femoral shaft fractures occurred. There was no statistically significant difference in the functional recovery score, reoperation, and mortality rates between the 2 groups. A new type of complication, the so-called Z-effect phenomenon, was noticed in the cephalomedullary nail group. There are no statistically significant differences between the two techniques in terms of type and rate of complications, functional outcome, reoperation and mortality rates when comparing the SHS and the cephalomedullary nail for low-energy AO/OTA 31A intertrochanteric fractures. Our data do not support recommendations for the use of one implant over the other.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)

  Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...

متن کامل

Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures

BACKGROUND Intertrochanteric hip fractures are common and devastating injuries especially for the elderly. Surgical treatment is the optimal strategy for managing intertrochanteric fractures as it allows early rehabilitation and functional recovery. The relative effects of internal fixation strategies for intertrochanteric fracture after operation remain limited to relatively small studies whic...

متن کامل

Treatment of Intertrochanteric Fractures Using the Compression Hip Nail

PURPOSE To investigate the clinical and radiologic outcomes following treatment of intertrochanteric fractures using the Compression Hip Nail® (CHN), which has a sliding lag screw. MATERIALS AND METHODS Twenty-eight cases of intertrochanteric fractures treated with CHN from November 2012 to October 2013 and followed-up for >6 months were included. The patient population consisted of 11 men an...

متن کامل

TRIGEN INTERTAN intramedullary nail versus sliding hip screw: a prospective, randomized multicenter study on pain, function, and complications in 684 patients with an intertrochanteric or subtrochanteric fracture and one year of follow-up.

BACKGROUND Both intramedullary nails and sliding hip screws are used with good results in the treatment of intertrochanteric and subtrochanteric fractures. The aim of our study was to assess whether use of the TRIGEN INTERTAN nail, as compared with a sliding hip screw, resulted in less postoperative pain, improved functional mobility, and reduced surgical complication rates for patients with an...

متن کامل

Factors influencing functional outcomes in united intertrochanteric hip fractures: a negative effect of lag screw sliding.

The purpose of this study was to investigate the factors influencing functional outcomes in elderly patients with united intertrochanteric fractures treated with hip nails and to ascertain whether decreased femoral offset due to lag screw sliding has a negative effect on functional outcomes in these patients. This retrospective study included 65 patients older than 65 years with united intertro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -