Assessment of technique for rapid detection of Escherichia coli and Proteus species in urine by head-space gas-liquid chromatography.
نویسندگان
چکیده
A test depending on the production of ethanol by Escherichia coli from lactose and dimethyl disulfide by Proteus spp. from methionine in the early exponential phase of growth and the detection of these products by head-space gas-liquid chromatography has been applied to 75 specimens of urine selected to provide the most stringent trial of the test. The test was found to be rapid and reliable for the commonest findings in the microbiological examination of urine. In 3 to 4 h it detected "significant" numbers (greater than 10(5)/ml) of E. coli or of Proteus mirabilis or P. inconstans A, identified as Proteus spp., in 23 urines. It recorded the absence of infection from 32 urines containing borderline or "not significant" numbers of any organism. Significant numbers of other organisms in 13 urines were not mistaken for E. coli or Proteus spp. However, the test was less successful for some less common findings. Klebsiella ozenae in significant numbers in one urine was mistaken for E. coli. P. morganii in significant numbers in one urine was not detected. E. coli or P. mirabilis mixed with significant numbers of another organism were not detected in four out of five urines. The technique is simple and could be automated. It appears to merit more extensive trial in a hospital laboratory and further development to detect and correctly identify more species that cause urinary tract infections.
منابع مشابه
Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملMethyl mercaptan and dimethyl disulfide production from methionine by Proteus species detected by head-space gas-liquid chromatography.
Head-space gas-liquid chromatography and mass spectrometry were used to detect and identify products formed by Proteus vulgaris, P. mirabilis, P. morganii, and P. rettgeri from a defined medium supplemented with either phenylalanine, methionine, valine, leucine, histidine, lysine, ornithine, threonine, asparagine, aspartic acid, or tryptophan. In a detailed study of the products formed by 68 st...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملDetermination of Synthetic Phenolic Antioxidants in Biological Fluids Based on Air-assisted Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
An air–assisted liquid–liquid microextraction method for the extraction and preconcentration of trace amounts of some synthetic phenolic antioxidants in biological fluids followed by their determination by gas chromatography–flame ionization detection has been reported. In this method the target analytes are extracted into a few microliters of carbon tetrachloride (extraction solvent) from an a...
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 6 3 شماره
صفحات -
تاریخ انتشار 1977