Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Prazosin, Terazosin, and Doxazosin in Pharmaceutical Formulations

نویسندگان

  • Alankar Shrivastava
  • Vipin B. Gupta
چکیده

The current study was carried out with an attempt to separate similarly structured title drugs by liquid chromatography. Spectrophotometric techniques were generally insufficient under these conditions because of the spectral overlapping of drugs with similar functional groups. The pharmaceutical drugs prazosin, terazosin, and doxazosin contain the same parent quinazoline nucleus, thus making it especially difficult to separate the former two drugs because of their very similar structures. A simple and sensitive method for the routine determination of these drugs in pharmaceutical formulations was attempted. We found that the mobile phase consisting of A: ACN-diethylamine (0.05 ml), B: methanol, and C: 10 mM Ammonium acetate separated these drugs effectively. Separations were carried out on a new Kromasil C18 column (250 × 4.6 mm, 5.0 μm) at 254 nm wavelength. The calibration curve was found to be linear in the range of 2-500 μg/ml. The stated method was then validated in terms of specificity, linearity, precision, and accuracy. Additionally, the proposed method reduced the duration of the analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 80  شماره 

صفحات  -

تاریخ انتشار 2012