Measuring Three-Dimensional Thorax Motion Via Biplane Radiographic Imaging: Technique and Preliminary Results.

نویسندگان

  • Timothy G Baumer
  • Joshua W Giles
  • Anne Drake
  • Roger Zauel
  • Michael J Bey
چکیده

Measures of scapulothoracic motion are dependent on accurate imaging of the scapula and thorax. Advanced radiographic techniques can provide accurate measures of scapular motion, but the limited 3D imaging volume of these techniques often precludes measurement of thorax motion. To overcome this, a thorax coordinate system was defined based on the position of rib pairs and then compared to a conventional sternum/spine-based thorax coordinate system. Alignment of the rib-based coordinate system was dependent on the rib pairs used, with the rib3:rib4 pairing aligned to within 4.4 ± 2.1 deg of the conventional thorax coordinate system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of biplane x-ray imaging combined with model-based tracking for measuring in-vivo patellofemoral joint motion

BACKGROUND Accurately measuring in-vivo motion of the knee's patellofemoral (PF) joint is challenging. Conventional measurement techniques have largely been unable to accurately measure three-dimensional, in-vivo motion of the patella during dynamic activities. The purpose of this study was to assess the accuracy of a new model-based technique for measuring PF joint motion. METHODS To assess ...

متن کامل

Three-dimensional dynamic in vivo motion of the cervical spine: assessment of measurement accuracy and preliminary findings.

BACKGROUND CONTEXT Previous research has quantified cervical spine motion with conventional measurement techniques (eg, cadaveric studies, motion capture systems, and fluoroscopy), but these techniques were not designed to accurately measure three-dimensional (3D) dynamic cervical spine motion under in vivo conditions. PURPOSE The purposes of this study were to characterize the accuracy of mo...

متن کامل

Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Shoulder motion is complex and significant research efforts have focused on measuring glenohumeral joint motion. Unfortunately, conventional motion measurement techniques are unable to measure glenohumeral joint kinematics during dynamic shoulder motion to clinically significant levels of accuracy. The purpose of this study was to validate the accuracy of a new model-based tracking technique fo...

متن کامل

In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency.

Dynamic assessment of three-dimensional (3D) skeletal kinematics is essential for understanding normal joint function as well as the effects of injury or disease. This paper presents a novel technique for measuring in-vivo skeletal kinematics that combines data collected from high-speed biplane radiography and static computed tomography (CT). The goals of the present study were to demonstrate t...

متن کامل

Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.

While measuring knee motion in all six degrees of freedom is important for understanding and treating orthopaedic knee pathologies, traditional motion capture techniques lack the required accuracy. A variety of model-based biplane fluoroscopy techniques have been developed with sub-millimeter accuracy. However, no studies have statistically evaluated the consistency of the accuracy across motio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 138 1  شماره 

صفحات  -

تاریخ انتشار 2016