Feasibility Study of Compton Scattering Enhanced Multiple Pinhole Imager for Nuclear Medicine.
نویسندگان
چکیده
This paper presents a feasibility study of a Compton scattering enhanced (CSE) multiple pinhole imaging system for gamma rays with energy of 140keV or higher. This system consists of a multiple-pinhole collimator, a position sensitive scintillation detector as used in standard Gamma camera, and a Silicon pad detector array, inserted between the collimator and the scintillation detector. The problem of multiplexing, normally associated with multiple pinhole system, is reduced by using the extra information from the detected Compton scattering events. In order to compensate for the sensitivity loss, due to the low probability of detecting Compton scattered events, the proposed detector is designed to collect both Compton scattering and Non-Compton events. It has been shown that with properly selected pinhole spacing, the proposed detector design leads to an improved image quality.
منابع مشابه
Compton scattering as a probe for materials investigation
This article investigates into the feasibility of using gamma radiation Compton backscatter spectra as a means of material characterization, with the view to developing a portable, hand held probe for investigative purposes such as searching for illicit substances hidden in wall or car door cavities.
متن کاملDetermining the accuracy of measuring the thickness of steel plates using Compton scattering method
When there is limitation access to one side of the structure in industry, one of the best methods for thickness measurements is the Compton scattering. In this paper, due to the statistical behavior of dispersed beam counting, we discuss the accuracy of the measurement for steel thickness. Using the experimental method and comparing it with MCNP simulation code, the accuracy is obtained less th...
متن کاملSPECT low-field MRI system for small-animal imaging.
UNLABELLED Localization of regions with increased uptake of radiotracer in small-animal SPECT is greatly facilitated when using coregistration with anatomic images of the same animal. As MRI has several advantages compared with CT (soft-tissue contrast and lack of ionizing radiation) we developed a SPECT/low-field MRI hybrid device for small-animal imaging. METHODS A small-animal single-pinho...
متن کاملStudy of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method
Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...
متن کاملSimulation and patient studies of scatter correction in cardiac SPECT imaging
Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on nuclear science
دوره 2 شماره
صفحات -
تاریخ انتشار 2002