Increased Natural Ventilation Flow Rates through Ventilation Shafts
نویسندگان
چکیده
Buoyancy-driven natural ventilation in ventilation shafts is investigated with a small scale physical experiment within a duct and CFD simulations of an office building. For a fixed exhaust opening, smaller shafts lead to higher flow rates in upper floors of a multi-story building with a shared ventilation shaft. These higher flow rates are caused by increased vertical momentum within the smaller shafts that induce flow through upper floors, an effect referred to as the “ejector effect.” In the small scale duct, a 0.5 m by 0.5 m shaft leads to a slight reverse flow of 0.0029 m 3 /s through the upper floor. Holding all other parameters constant and reducing the shaft to 0.25 m by 0.5 m leads to a positive flow rate of 0.012 m 3 /s through the upper floor. In the CFD simulations of a three story office building, this same pattern is observed. A 3 m by 2 m shaft leads to a flow rate of 0.0168 m 3 /s through the third floor, while the reduced shaft of 2 m by 2 m leads to a flow rate of 0.766 m 3 /s through the same floor. This increased airflow rate from the ejector effect can allow natural ventilation to be used in buildings where it may otherwise have been deemed inappropriate. Most airflow network models neglect air momentum and fail to account for the ejector effect. To improve these models, an empirical model is incorporated into the airflow network model CoolVent in a manner easily transferable to most airflow network models.
منابع مشابه
Experimental and numerical study of natural ventilation in four-sided wind tower traps
In the past, wind towers were applied as the main architectural part of building construction in the desert areas of Iran. These almost high structures were used as cooling load suppliers at residential buildings. In the present study, the effect of symmetric four-sided wind tower in flow induction to the bottom space has been analysed by using a wind tunnel and numerical simulations. In the nu...
متن کاملGeysering generated by large air pockets released through water-filled ventilation shafts
One potential problem affecting below-grade stormwater storage tunnels is the occurrence of geysering, which is defined as the return of conveyed water to grade. Most investigations to date have linked this occurrence with inertial oscillation of the water within vertical shafts. Another mechanism that can lead to geysering is the release of air and water through ventilation towers. This study ...
متن کاملCurrent and Likely Future Performance of Advanced Natural Ventilation
Advanced natural ventilation (ANV), often characterised by the use of dedicated ventilation stacks, shafts and other architecture features such as atria, light wells, has gained popularity for natural ventilation design in recent decades. In this research, a prototype ANV system is proposed, and the likely thermal performance in a range of UK climatic conditions predicted using dynamic thermal ...
متن کاملThe role of natural ventilation on reducing indoor radon concentration
Due to the increasing of closed ventilation systems used in buildings, the risk of indoor radon is increased day by day. In this study, we selected two sample rooms to calculate the radon emission coefficient from different levels, radon concentration measured when the natural ventilation was completely closed and compared with the analytical results. The results clearly show the difference in ...
متن کاملNumerical studies on natural ventilation flow in an enclosure with both buoyancy and wind effects
Computational Fluid Dynamics (CFD) is used to predict natural ventilation flows in an enclosure with upper and lower openings connected to the environment. The natural driving forces are wind combined with buoyancy. CFD simulations were carried out by varying the strengths of buoyancy under a constant assisting wind effect. Simulation results of the volume flow rates through the enclosure, the ...
متن کامل