Treatment of nasopharyngeal carcinoma using simultaneous modulated accelerated radiation therapy via helical tomotherapy: a phase II study

نویسندگان

  • Lei Du
  • Xin Xin Zhang
  • Lin Chun Feng
  • Jing Chen
  • Jun Yang
  • Hai Xia Liu
  • Shou Ping Xu
  • Chuan Bin Xie
  • Lin Ma
چکیده

BACKGROUND The aim of the study was to evaluate short-term safety and efficacy of simultaneous modulated accelerated radiation therapy (SMART) delivered via helical tomotherapy in patients with nasopharyngeal carcinoma (NPC). METHODS Between August 2011 and September 2013, 132 newly diagnosed NPC patients were enrolled for a prospective phase II study. The prescription doses delivered to the gross tumor volume (pGTVnx) and positive lymph nodes (pGTVnd), the high risk planning target volume (PTV1), and the low risk planning target volume (PTV2), were 67.5 Gy (2.25 Gy/F), 60 Gy (2.0 Gy/F), and 54 Gy (1.8 Gy/F), in 30 fractions, respectively. Acute toxicities were evaluated according to the established RTOG/EORTC criteria. This group of patients was compared with the 190 patients in the retrospective P70 study, who were treated between September 2004 and August 2009 with helical tomotherapy, with a dose of 70-74 Gy/33F/6.5W delivered to pGTVnx and pGTVnd. RESULTS The median follow-up was 23.7 (12-38) months. Acute radiation related side-effects were mainly problems graded as 1 or 2. Only a small number of patients suffered from grade 4 leucopenia (4.5%) or thrombocytopenia (2.3%). The local relapse-free survival (LRFS), nodal relapse-free survival (NRFS), local-nodal relapse-free survival (LNRFS), distant metastasis-free survival (DMFS) and overall survival (OS) were 96.7%, 95.5%, 92.2%, 92.7% and 93.2%, at 2 years, respectively, with no significant difference compared with the P70 study. CONCLUSIONS Smart delivered via the helical tomotherapy technique appears to be associated with an acceptable acute toxicity profile and favorable short-term outcomes for patients with NPC. Long-term toxicities and patient outcomes are under investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Advances and challenges in intensity-modulated radiotherapy for nasopharyngeal carcinoma.

Nasopharyngeal carcinoma is an endemic disease within specific regions in the world. Radiotherapy is the main treatment. In recent decades, intensity-modulated radiation therapy has undergone a rapid evolution. Compared with two-dimensional radiotherapy and/or three-dimensional conformal radiotherapy, evidence has shown it may improve quality of life and prognosis for patients with nasopharynge...

متن کامل

Clinical evaluation of simultaneous integrated boost in brain metastasis patients with helical intensity modulated radiotherapy

Background: This study was performed to assess patient survival and treatment toxicity after helical tomotherapy (HT) with simultaneous integrated boost (SIB) radiotherapy (RT) for cancer patients with one to eight brain metastases (BM) who have been treated with or without surgery. Materials and Methods: A total of 48 brain metastasis (BM) patients were included in this retrospective study bet...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2016