Quantitative analysis of near-implant magnesium accumulation for a Si-containing coated AZ31 cage from a goat cervical spine fusion model

نویسندگان

  • Fan Zhang
  • Haocheng Xu
  • Hongli Wang
  • Fang Geng
  • Xiaosheng Ma
  • Minghao Shao
  • Shun Xu
  • Feizhou Lu
  • Jianyuan Jiang
چکیده

BACKGROUND Magnesium (Mg) released from Mg-based implants degradation is believed to be effective in improving osteogenesis, however, studies focusing on Mg-based interbody cages are limited and fusion success was never reported. As excessive Mg accumulation can inhibit new bone formation, this study is designed to explain the possible reasons for the fusion failure of Mg-based cages by analyzing the relationships between the intervertebral Mg accumulation and the resulting interbody fusion. METHODS The experimental cage was consisted of magnesium alloy (AZ31) substrate and Silicon (Si) -containing coating. C3/C4 and C5/C6 of 24 goats were implanted with cage or autologous iliac crest bone graft (Control group), which were analyzed at 3, 6, 12, and 24 weeks post-operatively. Intervertebral Mg concentrations, Mg-related Calcium (Ca)/ Phosphorus (P) ratios, radiological evaluations and histological findings were recorded for analyzing the relationships between the three of cage corrosion, Mg accumulation, and interbody fusion. RESULTS Intervertebral Mg levels were significantly increased after cage implantation, especially in the areas that were closer to the cages at 3 weeks post-operatively, and these increased concentrations could persist up to 12 weeks post-operatively, indicating a relatively rapid corrosion process. Significantly lower Mg levels were only found at 24 weeks post-operatively, but these levels were still higher than those of the control group. In addition, Mg was found to be widely distributed at the intervertebral space since high Mg concentrations could even be detected at the posterior boundary of the vertebral body. Under this Mg accumulation profile, interbody fusion was not achieved, as indicated by the decreased Ca/P ratios, low CT fusion scores and negative histological results. CONCLUSIONS Intervertebral excessive Mg accumulation might be the primary reason for interbody fusion failure. Quantitative Mg analysis can offer insight into the association between cage degeneration and biological response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioabsorbable self-retaining PLA/nano-sized β-TCP cervical spine interbody fusion cage in goat models: an in vivo study

STUDY DESIGN This is an experimental animal study. OBJECTIVE The objective of this study was to compare an anterior cervical discectomy and interbody fusion of a novel polylactide/nano-sized β-tricalcium phosphate (PLA/nβ-TCP) bioabsorbable self-retaining cervical fusion cage (BCFC) with an autologous bone graft and polyetheretherketone (PEEK) cages. BACKGROUND Although PLA cervical cages h...

متن کامل

Comparison of outcomes and safety of using hydroxyapatite granules as a substitute for autograft in cervical cages for anterior cervical discectomy and interbody fusion

Background:   After cervical discectomy, autogenetic bone is packed into the cage to increase the rate of union between adjacent vertebral bodies, but donor site–related complications can still occur. In this study we evaluate the use   of hydroxyapatite granules as a substitute for autograft for interbody fusion.     Methods:   From November 2008 to November 2011, 236 patients participated in ...

متن کامل

Osteoinductive activity of ErhBMP-2 after anterior cervical diskectomy and fusion with a ß-TCP interbody cage in a goat model.

Bone morphogenetic protein (BMP)-2 induces bone and cartilage tissue formation. Large amounts of BMP-2 are difficult to purify or to produce in vitro using eukaryotic cells. The goal of the present study was to assess the clinical use of Escherichia coli-derived recombinant human BMP-2 (ErhBMP-2) on bone fusion after cervical and lumbar spine surgery in a goat model, compared with the standard ...

متن کامل

Preliminary results in anterior cervical discectomy and fusion with an experimental bioabsorbable cage – clinical and radiological findings in an ovine animal model

BACKGROUND Bioabsorbable implants are not widely used in spine surgery. This study investigated the clinical and radiological findings after anterior cervical discectomy and fusion (ACDF) in an ovine animal model with an experimental bioabsorbable cage consisting of magnesium and polymer (poly-ϵ-caprolactone, PCL) in comparison to a tricortical bone graft as the gold standard procedure. MATER...

متن کامل

Anterior Cervical Corpectomy Non-Fusion Model Produced by a Novel Implant.

BACKGROUND Anterior cervical corpectomy and fusion are frequently used in the treatment of cervical spinal disease. However, the range of motion (ROM) of the operative level is unavoidably lost due to fusion. This study aims to establish an anterior cervical corpectomy goat non-fusion model and to evaluate the ROM of adjacent and operative levels. MATERIAL/METHODS Six adult-male goats (in viv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018