Music perception with temporal cues in acoustic and electric hearing.
نویسندگان
چکیده
OBJECTIVE The first specific aim of the present study is to compare the ability of normal-hearing and cochlear implant listeners to use temporal cues in three music perception tasks: tempo discrimination, rhythmic pattern identification, and melody identification. The second aim is to identify the relative contribution of temporal and spectral cues to melody recognition in acoustic and electric hearing. DESIGN Both normal-hearing and cochlear implant listeners participated in the experiments. Tempo discrimination was measured in a two-interval forced-choice procedure in which subjects were asked to choose the faster tempo at four standard tempo conditions (60, 80, 100, and 120 beats per minute). For rhythmic pattern identification, seven different rhythmic patterns were created and subjects were asked to read and choose the musical notation displayed on the screen that corresponded to the rhythmic pattern presented. Melody identification was evaluated with two sets of 12 familiar melodies. One set contained both rhythm and melody information (rhythm condition), whereas the other set contained only melody information (no-rhythm condition). Melody stimuli were also processed to extract the slowly varying temporal envelope from 1, 2, 4, 8, 16, 32, and 64 frequency bands, to create cochlear implant simulations. Subjects listened to a melody and had to respond by choosing one of the 12 names corresponding to the melodies displayed on a computer screen. RESULTS In tempo discrimination, the cochlear implant listeners performed similarly to the normal-hearing listeners with rate discrimination difference limens obtained at 4-6 beats per minute. In rhythmic pattern identification, the cochlear implant listeners performed 5-25 percentage points poorer than the normal-hearing listeners. The normal-hearing listeners achieved perfect scores in melody identification with and without the rhythmic cues. However, the cochlear implant listeners performed significantly poorer than the normal-hearing listeners in both rhythm and no-rhythm conditions. The simulation results from normal-hearing listeners showed a relatively high level of performance for all numbers of frequency bands in the rhythm condition but required as many as 32 bands in the no-rhythm condition. CONCLUSIONS Cochlear-implant listeners performed normally in tempo discrimination, but significantly poorer than normal-hearing listeners in rhythmic pattern identification and melody recognition. While both temporal (rhythmic) and spectral (pitch) cues contribute to melody recognition, cochlear-implant listeners mostly relied on the rhythmic cues for melody recognition. Without the rhythmic cues, high spectral resolution with as many as 32 bands was needed for melody recognition for normal-hearing listeners. This result indicates that the present cochlear implants provide sufficient spectral cues to support speech recognition in quiet, but they are not adequate to support music perception. Increasing the number of functional channels and improved encoding of the fine structure information are necessary to improve music perception for cochlear implant listeners.
منابع مشابه
Musical Instrument Recognition in Combined Electric and Acoustic Cochlear Implant Simulations
The present study investigated listeners’ performance in a closed-set musical instrument recognition task through simulations of a cochlear implant (CI) and electric-acoustic stimulation (EAS), where the use of a CI is supplemented by a hearing aid to access low-frequency residual hearing. The recognition rates varied across the different musical instruments, with higher scores for instruments ...
متن کاملEmotional Perception of Music in Children with Unilateral Cochlear Implants
Introduction: Cochlear implantation (CI) improves language skills among children with hearing loss. However, children with CIs still fall short of fulfilling some other needs, including musical perception. This is often attributed to the biological, technological, and acoustic limitations of CIs. Emotions play a key role in the understanding and enjoyment of music. The present study aimed to in...
متن کاملPsychophysical properties of low-frequency hearing: implications for perceiving speech and music via electric and acoustic stimulation.
We have investigated the psychophysical properties of low-frequency hearing, both before and after implantation, to see if we can account for the benefit to speech understanding and melody recognition of adding acoustic stimulation to electric stimulation. In this paper, we review our work and the work of others and describe preliminary results not previously published. We show (a) that it is p...
متن کاملSpeech and melody recognition in binaurally combined acoustic and electric hearing.
Speech recognition in noise and music perception is especially challenging for current cochlear implant users. The present study utilizes the residual acoustic hearing in the nonimplanted ear in five cochlear implant users to elucidate the role of temporal fine structure at low frequencies in auditory perception and to test the hypothesis that combined acoustic and electric hearing produces bet...
متن کاملAcoustic Sensitivity of the Saccule and Daf Music
Introduction: The daf is a large Persian frame drum used as a musical instrument in both popular and classical music which can induce a percussive sound at low frequencies (146–290 Hz) with peaks of up to 130 dBspl. The percussive sounds have a power distribution in the region of saccular sensitivity. In view of the saccular stimulation by sound in humans, we decided to use cervical vestibu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ear and hearing
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2004