Influence of glenoid component design and humeral component retroversion on internal and external rotation in reverse shoulder arthroplasty: a cadaver study.
نویسندگان
چکیده
BACKGROUND A common disadvantage of reverse shoulder arthroplasty is limitation of the range of arm rotation. Several changes to the prosthesis design and implantation technique have been suggested to improve rotation range of motion (ROM). HYPOTHESIS Glenoid component design and degree of humeral component retroversion influence rotation ROM after reverse shoulder arthroplasty. MATERIAL AND METHODS The Aequalis Reversed™ shoulder prosthesis (Tornier Inc., Edina, MN, USA) was implanted into 40 cadaver shoulders. Eight glenoid component combinations were tested, five with the 36-mm sphere (centred seating, eccentric seating, inferior tilt, centred with a 5-mm thick lateralised spacer, and centred with a 7-mm thick lateralised spacer) and three with the 42-mm sphere (centred with no spacer or with a 7-mm or 10-mm spacer). Humeral component position was evaluated with 0°, 10°, 20°, 30°, and 40° of retroversion. External and internal rotation ROMs to posterior and anterior impingement on the scapular neck were measured with the arm in 20° of abduction. RESULTS The large glenosphere (42 mm) was associated with significantly (P<0.05) greater rotation ROMs, particularly when combined with a lateralised spacer (46° internal and 66° external rotation). Rotation ROMs were smallest with the 36-mm sphere. Greater humeral component retroversion was associated with a decrease in internal rotation and a significant increase (P<0.05) in external rotation. The best balance between rotation ROMs was obtained with the native retroversion, which was estimated at 17.5° on average in this study. DISCUSSION Our anatomic study in a large number of cadavers involved a detailed and reproducible experimental protocol. However, we did not evaluate the variability in scapular anatomy. Earlier studies of the influence of technical parameters did not take humeral component retroversion into account. In addition, no previous studies assessed rotation ROMs. CONCLUSION Rotation ROM should be improved by the use of a large-diameter glenosphere with a spacer to lateralise the centre of rotation of the gleno-humeral joint, as well as by positioning the humeral component at the patient's native retroversion value.
منابع مشابه
Effect of Humeral Component Version on Outcomes in Reverse Shoulder Arthroplasty.
Although reverse shoulder arthroplasty provides excellent clinical results in appropriately selected patients, loss of external and internal rotation may occur. Component selection, design, and placement affect postoperative results. Recent studies considered the effect of humeral component version on functional results. The current study investigated whether humeral stem retroversion affects t...
متن کاملComparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study
Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty.Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and theuse of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objectiveis to report the radiographic outcomes of patie...
متن کاملReverse Total Shoulder Arthroplasty With Humeral Head Autograft Fixed Onto Glenoid for Treatment of Severe Glenoid Retroversion
Advanced glenohumeral osteoarthritis can transform glenoid morphology and, in some cases, is found in association with severe glenoid retroversion. The associated glenoid retroversion leads to difficulty in fixation of the glenoid component in reverse total shoulder arthroplasty. In the context of extreme glenoid wear, structural grafts can be used to restore glenoid volume and version in order...
متن کاملOsseous adaptation and range of motion at the glenohumeral joint in professional baseball pitchers.
The throwing shoulder in pitchers frequently exhibits a paradox of glenohumeral joint motion, in which excessive external rotation is present at the expense of decreased internal rotation. The object of this study was to determine the role of humeral head retroversion in relation to increased glenohumeral external rotation. Glenohumeral joint range of motion and laxity along with humeral head a...
متن کاملBiomechanical benefits of anterior offsetting of humeral head component in posteriorly unstable total shoulder arthroplasty: A cadaveric study.
Restoration of joint stability during total shoulder arthroplasty can be challenging in the face of severe glenoid retroversion. A novel technique of humeral head component anterior-offsetting has been proposed to address posterior instability. We evaluated the biomechanical benefits of this technique in cadaveric specimens. Total shoulder arthroplasty was performed in 14 cadaveric shoulders fr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopaedics & traumatology, surgery & research : OTSR
دوره 99 8 شماره
صفحات -
تاریخ انتشار 2013