Comparison between methods of assessing lumbosacral curve obtained by radiographic image
نویسندگان
چکیده
OBJECTIVE To investigate the correlation between different radiographic methods in the evaluation of the lumbosacral concavity. METHODS The sample consisted of 52 individuals with ages ranging from 18 to 28 years old. The procedures related to radiographic image collection were carried out in collaboration with a diagnostic imaging center of a hospital in Curitiba, PR, Brazil. The angles of the lumbosacral concavity were evaluated by the following methods: Centroid, Cobb1L1-S1, Cobb2L1-L5, Cobb3L2-S1 Cobb4T12-S1, Posterior Tangent and Trall. RESULTS High correlation coefficients (r ranging from 0.77 to 0.89) were found among variations of the Cobb method. Additionally, we propose a categorical classification of angle values obtained by each method. We also analyzed the influence of the level of the inflection point between the lumbar lordosis and thoracic kyphosis in determining the evaluation method to be used. The inflection point had a higher incidence in the region between the twelfth thoracic vertebra and the first lumbar vertebra (63.5%). CONCLUSION The correlation and agreement between methods vary considerably. Moreover, the thoracolumbar inflection point should be considered when choosing the method of assessing patients.
منابع مشابه
Dose Evaluation for Common Digital Radiographic Examinations in Selected Hospitals in Pahang Malaysia
Introduction: In digital radiography, radiographers tend to increase exposure factors to acquire an acceptable image quality thereby increasing radiation dose to patients. Regarding this, the present study aimed to re-evaluate the exposure parameters and to ascertain the entrance surface dose (ESD) and effective dose (ED) of posterior-anterior (PA) chest, abdomen, and anterior-posterior (AP) l...
متن کاملOptimization of Dose and Image Quality in Full-fiand Computed Radiography Systems for Common Digital Radiographic Examinations
IntroductionA fine balance of image quality and radiation dose can be achieved by optimization to minimize stochastic and deterministic effects. This study aimed in ensuring that images of acceptable quality for common radiographic examinations in digital imaging were produced without causing harmful effects. Materials and MethodsThe study was conducted in three phases. The pre-optimization inv...
متن کاملThe perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs
Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...
متن کاملScoliotic posture as the initial symptom in adolescents with lumbar disc herniation: its curve pattern and natural history after lumbar discectomy
BACKGROUND There have been few studies focusing on the curve pattern of scoliosis caused by lumbar disc herniation (LDH) in adolescents and the natural history of scoliosis after discectomy. The current study was carried out to identify the curve pattern of scoliosis and investigate the effect of posterior discectomy on the curve improvement in adolescents with LDH. METHODS This review focuse...
متن کاملContent Based Radiographic Images Indexing and Retrieval Using Pattern Orientation Histogram
Introduction: Content Based Image Retrieval (CBIR) is a method of image searching and retrieval in a database. In medical applications, CBIR is a tool used by physicians to compare the previous and current medical images associated with patients pathological conditions. As the volume of pictorial information stored in medical image databases is in progress, efficient image indexing and retri...
متن کامل