The risk of stanford type-A aortic dissection with different tear size and location: a numerical study
نویسندگان
چکیده
BACKGROUND This study is to investigate the influence of hemodynamics on Stanford type-A aortic dissection with different tear size and location, to provide some support for the relationships between the risks (rupture, reverse tearing and further tearing) and tear size and location for clinical treatment. METHODS Four numerical models of Stanford type-A aortic dissection were established, with different size and location of the tears. The ratio of the area between the entry and re-entry tears(RA) is various within the model; while, the size and the location of the re-entry in the distal descending aorta are fixed. In model A11 and A21, the entry tears are located near the ascending aorta. The RA in these models are 1 and 2, respectively; In the model B11 and B21, the entry tears are located near the proximal descending aorta and the RA in these models are again assigned to 1 and 2, respectively. Then hemodynamics in these models was solved with numerically and the flow patterns and loading distributions were investigated. RESULTS The flow velocity of the true lumen in model A21, B21 is lower than that in A11, B11, respectively; the time-averaged wall shear stress (TAWSS) of the false lumen in model A21 and B21 is higher, and for ascending aorta false lumen, A11, A21 are higher than B11, B21, respectively. False lumen intimal wall pressure of A11, A21 are always higher than the true lumen ones. CONCLUSION The variation of the RA can significantly affect the dynamics of blood within the aortic dissection. When the entry tear size is larger than the re-entry tear ones, the false lumen, proximal descending aorta and the wall near re-entry tear are prone to cracking. Entry tear location can significantly alter the hemodynamics of aortic dissection as well. When entry tear location is closer to proximal ascending aorta, false lumen continues to expand and compress the true lumen resulting in the true lumen reduction. For proximal ascending aorta, high pressure in false lumen predicts a higher risk of reverse tear.
منابع مشابه
Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report
Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...
متن کاملAortic Dissection of Unknown Origin in a Young Patient: A Case Report
Aortic dissection occurs when a tear develops in the wall of the aorta, which is rare in the young population. This fatal disorder is hard to diagnose, especially in young patients. We present the case of aortic dissection in a 15-year-old boy referred to the Emergency Department of Yazd University of Medical Sciences in November 2015. The patient presented to our department with sudden acute c...
متن کاملComputational Study of Anatomical Risk Factors in Idealized Models of Type B Aortic Dissection.
OBJECTIVE/BACKGROUND Several risk factors have been identified in type B aortic dissection (TBAD), namely tear size, location, patency and number, and false lumen (FL) location. However, the individual impact of each of these factors is poorly understood. The impact of these factors was investigated using computational fluid dynamics (CFD). METHODS Fourteen idealized models of chronic TBAD we...
متن کاملگزارش شش مورد دیسکسیون حاد آئورت با علائم غیر معمولی
Acute aortic dissection is a common disease caused by primary tear in the aortic intima or rupture of vasa vasorum. Every year 5-30 per million are affected by that. Untreated aortic dissection (dissecting aortic aneurysm) carries a high mortality rate. More than 90% of acute dissections present with acute pain in chest or back or both. Aortic dissection may mimic other more common conditions...
متن کاملPrediction of thrombus formation using vortical structures presentation in Stanford type B aortic dissection: A preliminary study using CFD approach
False lumen patency has been recognized as the key determinant of aneurismal dilatation and rupture, whereas complete thrombosis has been proven clinically to improve disease outcomes. However, to date, there is no definitive method that could predict false lumen thrombosis in Stanford type B aortic dissection patient. The present study aims to use the evolution of vortical structures throughou...
متن کامل