Simultaneous measurements of sagittal knee laxity with an external device and radiostereometric analysis.

نویسندگان

  • L P Jorn
  • T Fridén
  • L Ryd
  • A Lindstrand
چکیده

We obtained simultaneous measurements of sagittal knee laxity in 12 consecutive patients after reconstruction of the anterior cruciate ligament (ACL), using the Stryker laxity tester and radiostereometric analysis (RSA). The mean anteroposterior (AP) displacement when a 90 N load was applied in both directions was 5.3 +/- 2.7 mm with RSA and 9.8 +/- 1.6 mm with the external device (p < 0.001). The corresponding measurements at a load of 180 N were 5.7 +/- 2.4 mm and 13.8 +/- 3.7 mm, respectively (p < 0.001). More than 50% of the sagittal knee movement, as measured by the external device at a load of 180 N, was not true femorotibial displacement of the joint but was due to soft-tissue deformation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic variations in multiplanar knee laxity influence landing biomechanics.

PURPOSE Females vary substantially in their multiplanar cyclic knee laxity changes across the menstrual cycle. The biomechanical implications of these cyclic changes are relatively unknown. Our purpose was to first cluster females based on their cyclic changes in anterior knee laxity (AKL), genu recurvatum (GR), varus-valgus (VV), and internal-external (IER) rotation knee laxity across the mens...

متن کامل

Simultaneous measurements of knee motion using an optical tracking system and radiostereometric analysis (RSA)

BACKGROUND AND PURPOSE Invasive methods are more reproducible and accurate than non-invasive ones when it comes to recording knee kinematics, but they are usually less accessible and less safe, mainly due to risk of infection. For this reason, non-invasive methods with passive markers are widely used. With these methods, varying marker sets based on a number of single markers, or sets of marker...

متن کامل

Identifying multiplanar knee laxity profiles and associated physical characteristics.

CONTEXT A single measure of knee laxity (ie, measurement of laxity in a single plane of motion) is probably inadequate to fully describe how knee joint laxity is associated with anterior cruciate ligament injury. OBJECTIVE To characterize interparticipant differences in the absolute and relative magnitudes of multiplanar knee laxity (ie, sagittal, frontal, and transverse planes) and examine p...

متن کامل

Three-Dimensional in vivo Motion Analysis of Knee Joint Laxity under Torsional Loading

Excessive knee joint laxity is often used as an indicator of joint disease or injury such as rupture of the anterior cruciate ligament (ACL). Although the ACL has been shown to contribute to rotational stability of the knee, clinical assessment devices are currently limited to anterior-posterior drawer measurements. The objective of this work was to design a methodology whereby in vivo knee joi...

متن کامل

Bench testing of a knee joint arthrometer.

The KT1000 and KT2000 knee joint arthrometers (MEDmetric Corp, San Diego, California) have been shown to overestimate the measurement of knee joint sagittal laxity. The purpose of this study was to investigate the accuracy of the KT arthrometers as measures of anterior and posterior linear displacement. The anterior and posterior linear displacements of 3 KT arthrometers (2 KT1000 arthrometers ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 80 1  شماره 

صفحات  -

تاریخ انتشار 1998