Determination of vessel cross-sectional area by thresholding in Radon space.
نویسندگان
چکیده
The cross-sectional area of a blood vessel determines its resistance, and thus is a regulator of local blood flow. However, the cross-sections of penetrating vessels in the cortex can be non-circular, and dilation and constriction can change the shape of the vessels. We show that observed vessel shape changes can introduce large errors in flux calculations when using a single diameter measurement. Because of these shape changes, typical diameter measurement approaches, such as the full-width at half-maximum (FWHM) that depend on a single diameter axis will generate erroneous results, especially when calculating flux. Here, we present an automated method--thresholding in Radon space (TiRS)--for determining the cross-sectional area of a convex object, such as a penetrating vessel observed with two-photon laser scanning microscopy (2PLSM). The thresholded image is transformed back to image space and contiguous pixels are segmented. The TiRS method is analogous to taking the FWHM across multiple axes and is more robust to noise and shape changes than FWHM and thresholding methods. We demonstrate the superior precision of the TiRS method with in vivo 2PLSM measurements of vessel diameter.
منابع مشابه
Determination of radon concentration in drinking water of Taft Township and evaluation of the annual effective dose
Background: Radioactive substances are water chemical contaminants. In this study, the concentration of radon was measured in drinking water supplies of Taft villages (part of Dehshir-Baft fault located in central part of Iran) and also Shirkooh area with granite rocks (containing uranium). Materials and Methods: This cross sectional research was conducted in fall 2013 and winter 2014 on the so...
متن کاملDetermination of Radon Level in Drinking Water in Mehriz Villages and Evaluation the Annual Effective Absorbed Dose
Introduction: Radon is one of the most radioactive elements that may be found in soil, air and water naturally. Presence of fault and also granitic rocks near the water sources can cause high radon levels in these water resources. Radon concentration of various drinking water sources And network In Mehriz Villages was measured from Anar- Mehriz fault and granite stone of Shirkooh area. Materia...
متن کاملDetermination of radon concentration in drinking water of Bam villages and evaluation of the annual effective dose
Background: Radon is one of the most important radioactive elements which is released by natural decay of available uranium and radium in the ground. The presence of radon gas is common, wherever those faults are located there. Radon concentration of various drinking water resources of Bam villages; located near Bam fault; was measured. Materials and Methods: This cross-sectional study was cond...
متن کاملDetection of Blood Vessels in Color Fundus Images using a Local Radon Transform
Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable a...
متن کاملLimitations of postmortem assessment of human coronary artery size and luminal narrowing: differential effects of tissue fixation and processing on vessels with different degrees of atherosclerosis.
Numerous studies have utilized histologic sections of coronary arteries as the standard for testing the validity of the angiographic determination of coronary artery dimensions. However, little attention has been given to artifactual dimensional changes that occur during fixation and histologic processing of tissues (dehydration, clearing, embedding, sectioning and staining). Using planimetric ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism
دوره 34 7 شماره
صفحات -
تاریخ انتشار 2014