Surgical Options for the Refractive Correction of Keratoconus: Myth or Reality

نویسندگان

  • L Fernández-Vega-Cueto
  • V Romano
  • R Zaldivar
  • C H Gordillo
  • F Aiello
  • D Madrid-Costa
  • J F Alfonso
چکیده

Keratoconus provides a decrease of quality of life to the patients who suffer from it. The treatment used as well as the method to correct the refractive error of these patients may influence on the impact of the disease on their quality of life. The purpose of this review is to describe the evidence about the conservative surgical treatment for keratoconus aiming to therapeutic and refractive effect. The visual rehabilitation for keratoconic corneas requires addressing three concerns: halting the ectatic process, improving corneal shape, and minimizing the residual refractive error. Cross-linking can halt the disease progression, intrastromal corneal ring segments can improve the corneal shape and hence the visual quality and reduce the refractive error, PRK can correct mild-moderate refractive error, and intraocular lenses can correct from low to high refractive error associated with keratoconus. Any of these surgical options can be performed alone or combined with the other techniques depending on what the case requires. Although it could be considered that the surgical option for the refracto-therapeutic treatment of the keratoconus is a reality, controlled, randomized studies with larger cohorts and longer follow-up periods are needed to determine which refractive procedure and/or sequence are most suitable for each case.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

[Functional results of contact lens correction and penetrating keratoplasty in keratoconus. Report 1. Analysis of resolution ability of the eye].

Comparative analysis of functional results of contact lens correction and penetrating keratoplasty (PKP) in keratoconus are presented. To assess resolution ability we considered visual acuity and contrast sensitivity. 117 patients (219 eyes) with stage I-IV keratoconus, wearing rigid gas-permeable contact lenses (RPCL), and 60 patients (64 eyes) after PKP were examined. In 69% patients after PK...

متن کامل

بررسی اصلاح قوز قرنیه با استفاده از قطعات ‏حلقوی داخل قرنیه‌ای فرارا

  Background and Objective: Evaluation of the results, safety, and stability of ferrara intracorneal ring segment (FICRS) implantation for Keratoconus correction (age range was 24.39±8.32 years).   Materials and Methods: In this clinical trial study, 64 eyes of 57 patients with keratoconus and clear cornea that had FICRS implantation were studied. Uncorrected visual acuity (UCVA), best-spectacl...

متن کامل

[Long-term results of lasik refractive error correction after penetrating keratoplasty in patients with keratoconus].

OBJECTIVE To evaluate the long term results of Lasik for residual refractive errors (RE) after penetrating keratoplasty (PKP) for keratoconus (KC). DESIGN Retrospective cohort. METHOD Records of 14 consecutive patients (19 eyes) who had Lasik after PKP for KC were retrospectively reviewed. In all eyes with refractive stability and suture removed before Lasik, far distance Visual Acuity with...

متن کامل

Characterization of corneal structure in keratoconus.

UNLABELLED The increasing volume of patients interested in refractive surgery and the new treatment options available for keratoconus have generated a higher interest in achieving a better characterization of this pathology. The ophthalmic devices for corneal analysis and diagnosis have experienced a rapid development during the past decade with the implementation of technologies such as the Pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017