Ex-Vivo Characterization of Bioimpedance Spectroscopy of Normal, Ischemic and Hemorrhagic Rabbit Brain Tissue at Frequencies from 10 Hz to 1 MHz

نویسندگان

  • Lin Yang
  • Ge Zhang
  • Jiali Song
  • Meng Dai
  • Can-Hua Xu
  • Xiuzhen Dong
  • Feng Fu
چکیده

Stroke is a severe cerebrovascular disease and is the second greatest cause of death worldwide. Because diagnostic tools (CT and MRI) to detect acute stroke cannot be used until the patient reaches the hospital setting, a portable diagnostic tool is urgently needed. Because biological tissues have different impedance spectra under normal physiological conditions and different pathological states, multi-frequency electrical impedance tomography (MFEIT) can potentially detect stroke. Accurate impedance spectra of normal brain tissue (gray and white matter) and stroke lesions (ischemic and hemorrhagic tissue) are important elements when studying stroke detection with MFEIT. To our knowledge, no study has comprehensively measured the impedance spectra of normal brain tissue and stroke lesions for the whole frequency range of 1 MHz within as short as possible an ex vivo time and using the same animal model. In this study, we established intracerebral hemorrhage and ischemic models in rabbits, then measured and analyzed the impedance spectra of normal brain tissue and stroke lesions ex vivo within 15 min after animal death at 10 Hz to 1 MHz. The results showed that the impedance spectra of stroke lesions significantly differed from those of normal brain tissue; the ratio of change in impedance of ischemic and hemorrhagic tissue with regard to frequency was distinct; and tissue type could be discriminated according to its impedance spectra. These findings further confirm the feasibility of detecting stroke with MFEIT and provide data supporting further study of MFEIT to detect stroke.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vivo Bioimpedance Spectroscopy Characterization of Healthy, Hemorrhagic and Ischemic Rabbit Brain within 10 Hz–1 MHz

Acute stroke is a serious cerebrovascular disease and has been the second leading cause of death worldwide. Conventional diagnostic modalities for stroke, such as CT and MRI, may not be available in emergency settings. Hence, it is imperative to develop a portable tool to diagnose stroke in a timely manner. Since there are differences in impedance spectra between normal, hemorrhagic and ischemi...

متن کامل

Bioimpedance Assessment of Oral Squamous Cell Carcinoma with Clinicopathological Correlation.

AIM Molecular alterations at membrane, cytosol and nuclear level in cancer cells/tissue show variations in bioimpedance measure. In the present study, bioimpedance assessment and comparison was investigated between oral squamous cell carcinoma (OSCC) and normal tissue. Study further involves clinicopathological correlation of bioimpedance values in OSCC. MATERIALS AND METHODS The present stud...

متن کامل

Loratadine- Loaded Thermoresponsive Hydogel : Characterization and Ex-vivo Rabbit Cornea Permeability Studies

Poor bioavailability of ophthalmic drops is mainly due to drainage through the nasal-lacrimal duct and a very low permeability through corneal epithelium. The aim of our study was to prepare and characterize an ocular hydrogel of loratadine, as an example of a lipophilic drug, to increase drug concentration and residence time at the site of action in the eye. In this study,a 23full factorial de...

متن کامل

Loratadine- Loaded Thermoresponsive Hydogel : Characterization and Ex-vivo Rabbit Cornea Permeability Studies

Poor bioavailability of ophthalmic drops is mainly due to drainage through the nasal-lacrimal duct and a very low permeability through corneal epithelium. The aim of our study was to prepare and characterize an ocular hydrogel of loratadine, as an example of a lipophilic drug, to increase drug concentration and residence time at the site of action in the eye. In this study,a 23full factorial de...

متن کامل

Review Article: Application of Electrical Impedance Spectroscopy in Bladder Cancer Screening

Introduction Bladder cancer is the most common malignancy in elderly people and most bladder cancers are transitional cell carcinomas (TCC). Bladder pathology is usually investigated visually by cystoscopy and this technique can represent different conditions ranging from simple inflammation to flat CIS. However, biopsies must be taken from the suspected area to obtain diagnostic information. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016