Computerized assessment of angiographic occlusion rate and coil density in embolized human cerebral aneurysms.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Computerized methods have been introduced for more objective quantification of angiographic occlusion rate and coil density as parameters of successful embolization. This study aimed 1) to evaluate this new computerized method for angiographic occlusion rating and coil density calculations by comparison with corresponding histometric parameters from retrieved human aneurysms, and 2) to compare the new computerized method with the present standard of subjective angiographic occlusion rating. MATERIALS AND METHODS From 14 postmortem-retrieved human aneurysms, angiographic occlusion rate was determined by contrast medium attenuation-gradient distinction on digital subtraction angiographs after Guglielmi detachable coil (GDC) embolization. Angiographic coil density was calculated, approximating aneurysms as ellipsoid and coils as cylindric volumes. On surface-stained histologic ground sections of the respective aneurysms, the occluded aneurysm area and coil area were measured. Then, we calculated and compared the histometric occlusion rates and coil densities with the corresponding angiographic parameters by using the Wilcoxon paired signed-rank test and the Spearman rank correlation. RESULTS Computerized angiographic occlusion rates (75%-100%) showed good correlation (r = 0.799; P < .01) with histometric occlusion-rates (61%-100%), resulting in no statistically significant differences (P = .2163). With 5.1% (+/-3.8), the mean difference between computerized angiographic occlusion rates and histometry was substantially lower compared with 10.7% (+/-8.7) mean difference between subjective angiographic estimations and histometry. Calculated angiographic coil density (13%-32%) significantly differed from histometric coil density (8%-35%; P < .05). CONCLUSIONS For recanalized aneurysms, computerized angiographic occlusion rating showed better correspondence with histometry compared with subjective angiographic occlusion rating. Clinical application of this new tool may lead to more objective cutoff values for re-embolization indications. The value of coil density calculations seems limited by the approximation of the aneurysms as ellipsoid volumes.
منابع مشابه
Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms.
BACKGROUND AND PURPOSE The long-term outcome of aneurysmal coil embolization has not been determined. We retrospectively analyzed the results of our cases treated with detachable coils and evaluated the long-term stability of embolized aneurysms. METHODS This study involved 100 aneurysms in 93 patients who underwent follow-up angiography > or = 3 months after initial treatment between Decembe...
متن کاملEndovascular treatment with bare platinum coils for middle cerebral artery aneurysms.
Middle cerebral artery (MCA) aneurysms often have unfavorable anatomical characteristics preventing successful endovascular occlusion. We reviewed the outcomes of our series of endosaccular embolization of MCA aneurysms using bare platinum coils, angiographic images, and medical records. Immediate and follow-up angiographic results were categorized as complete occlusion, residual neck, and resi...
متن کاملThe impact of coil shape design on angiographic occlusion, packing density and coil mass uniformity in aneurysm embolization: an in vitro study.
OBJECTIVE To investigate the impact of coil design on the distribution of the coil mass in a controlled in vitro experiment. A secondary objective was to study the relationship between angiographic occlusion, packing density and coil mass uniformity. METHODS Seven silicon side wall aneurysm models were embolized in each arm with a different coil design under fluoroscopic guidance. Packing den...
متن کامل3D computerized occlusion rating of embolized experimental aneurysms using noninvasive 1.5T MR imaging.
BACKGROUND AND PURPOSE For embolized cerebral aneurysms, the initial occlusion rate is the most powerful parameter to predict aneurysm rerupture and recanalization. However, the occlusion rate is only estimated subjectively in clinical routine. To minimize subjective bias, computer occlusion-rating (COR) was successfully validated for 2D images. To minimize the remaining inaccuracy of 2D-COR, C...
متن کاملAngiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil.
BACKGROUND AND PURPOSE A report directly comparing platinum coils, Matrix coils, and HydroCoils in a single animal model does not currently exist. We evaluated and compared the performance of these three products in the embolization of experimental aneurysms. METHODS Thirty-three elastase-induced saccular aneurysms were created in rabbits. Aneurysms were embolized with Matrix coils (n = 15), ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 5 شماره
صفحات -
تاریخ انتشار 2009