In-Depth Glycoproteomic Characterization of γ-Conglutin by High-Resolution Accurate Mass Spectrometry

نویسندگان

  • Silvia Schiarea
  • Lolita Arnoldi
  • Roberto Fanelli
  • Eric De Combarieu
  • Chiara Chiabrando
چکیده

The molecular characterization of bioactive food components is necessary for understanding the mechanisms of their beneficial or detrimental effects on human health. This study focused on γ-conglutin, a well-known lupin seed N-glycoprotein with health-promoting properties and controversial allergenic potential. Given the importance of N-glycosylation for the functional and structural characteristics of proteins, we studied the purified protein by a mass spectrometry-based glycoproteomic approach able to identify the structure, micro-heterogeneity and attachment site of the bound N-glycan(s), and to provide extensive coverage of the protein sequence. The peptide/N-glycopeptide mixtures generated by enzymatic digestion (with or without N-deglycosylation) were analyzed by high-resolution accurate mass liquid chromatography-multi-stage mass spectrometry. The four main micro-heterogeneous variants of the single N-glycan bound to γ-conglutin were identified as Man2(Xyl) (Fuc) GlcNAc2, Man3(Xyl) (Fuc) GlcNAc2, GlcNAcMan3(Xyl) (Fuc) GlcNAc2 and GlcNAc 2Man3(Xyl) (Fuc) GlcNAc2. These carry both core β1,2-xylose and core α1-3-fucose (well known Cross-Reactive Carbohydrate Determinants), but corresponding fucose-free variants were also identified as minor components. The N-glycan was proven to reside on Asn131, one of the two potential N-glycosylation sites. The extensive coverage of the γ-conglutin amino acid sequence suggested three alternative N-termini of the small subunit, that were later confirmed by direct-infusion Orbitrap mass spectrometry analysis of the intact subunit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution Mass Spectrometry and Accurate Mass Measurements with Emphasis on the Characterization of Peptides and Proteins by Matrix-assisted Laser Desorption/Ionization Time-of-Ñight Mass Spectrometry

Fundamental concepts of high-resolution mass spectrometry as it relates to the issue of accurate mass measurements are presented. Important issues speciÐc to magnetic sector instruments, Fourier transform ion cyclotron resonance and time-of-Ñight (TOF) methods are discussed. Recent high-resolution TOF measurements on peptides and proteins, ionized by matrix-assisted laser desorption/ionization ...

متن کامل

Evaluation of Nitrogen Diffusion in Plasma Nitrided Iron by Various

   Diffusion of nitrogen in plasma nitrided iron and structural evolution during the nitriding process were evaluated by several characterization techniques including optical microscopy (OM), microhardness depth profiling (HDP), scanning electron microscopy (SEM), x-ray diffraction (XRD), glow discharge optical emission spectroscopy (GDOES), and secondary ion mass spectroscopy (SIMS). Plasma ni...

متن کامل

Comparative N-Glycoproteomic and Phosphoproteomic Profiling of Human Placental Plasma Membrane between Normal and Preeclampsia Pregnancies with High-Resolution Mass Spectrometry

Preeclampsia is a serious complication of pregnancy, which affects 2-8% of all pregnancies and is one of the leading causes of maternal and perinatal mortality and morbidity worldwide. To better understand the molecular mechanisms involved in pathological development of placenta in preeclampsia, we used high-resolution LC-MS/MS technologies to construct a comparative N-glycoproteomic and phosph...

متن کامل

Monitoring the concentration of 238U, 232Th, 40K and 137Cs of soil in Anarak-Khour district, Central Iran

This study was conducted to determine the radioactivity concentration in soil samples of Anarak-Khour district located at central Iran. 48 soil samples from a depth of 10-15 cm were taken from seven different sites for monitoring. The radioactivity concentration of 238U, 232Th, 137Cs and 40K in soil samples was determined, using a high resolution (HPGe detector, p-type) γ-spectrometry by detect...

متن کامل

Challenges in the quality assurance of elemental and isotopic analyses in the nuclear domain benefitting from high resolution ICP-OES and sector field ICP-MS

Accurate analytical data reinforces fundamentally the meaningfulness of nuclear fuel performance assessments and nuclear waste characterization. Regularly lacking matrix-matched certified reference materials, quality assurance of elemental and isotopic analysis of nuclear materials remains a challenging endeavour. In this context, this review highlights various dedicated experimental approaches...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013