Changes of corneal endothelial cell density after EX-PRESS® Glaucoma shunt implantation: 2-year follow-up study
نویسندگان
چکیده
Purpose: To evaluate effects of the EX-PRESS® glaucoma filtering device on the corneal endothelial cell density (ECD) in eyes with open angle glaucoma (OAG). Designs: A prospective, non-comparative study. Methods: We prospectively evaluated the changes in the ECD, hexagonality, and coefficient of variation (CV) in 20 eyes of 19 patients who had an implantation of the EX-PRESS®. The type of glaucoma was exfoliation glaucoma in 6 eyes, uveitic glaucoma in 5 eyes, secondary glaucoma following vitrectomy in 4 eyes, primary OAG in 3 eyes, and neovascularization glaucoma in 2 eyes. Corneal specular microscopy was performed at the central cornea before, 1, and 2 years after the EXPRESS® implantation. Results: The mean ECD was 2008 cells/mm2 before the surgery, 1956 cells/mm2 at 1 year, and 1846 cells/mm2 at 2 years after the surgery which represent a decrease of 5.0% at 1 year and a further decrease of 9.4% at 2 years. The decrease in the ECD from baseline to 1 year was not statistically significant, however the decreases from the baseline to 2 years (P<.0001) and from 1 year to 2 years (P=.0001) were significant. There was a significant change in the CV between the baseline and 1 year (P=0.03), and the change between baseline and 2 years was close to a statistically significant difference (P=0.07). There was no significant change in hexagonality during the 2 years. Two eyes with low preoperative ECD had a marked decrease in the ECD at 2 years. Conclusions: There is a slow decrease in the ECD after the EX-PRESS® implantation.
منابع مشابه
Trabeculectomy Versus EX-PRESS Shunt Versus Ahmed Valve Implant: Short-term Effects on Corneal Endothelial Cells.
PURPOSE To evaluate short-term changes in corneal endothelial cells after trabeculectomy, EX-PRESS device implantation, and Ahmed valve implantation for the treatment of primary open-angle glaucoma. DESIGN Prospective, interventional, comparative case series with contralateral eye control study. METHODS We prospectively evaluated the changes in number, density, and shape of the corneal endo...
متن کاملCorneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device
PURPOSE To report a case of corneal decompensation due to the Ex-PRESS(®) mini glaucoma shunt device (Ex-PRESS). PATIENT AND METHODS A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months. RESULTS We observed partial decompensation of the corneal endothelium adjacent to the filterin...
متن کاملSurgical treatment of neovascular glaucoma with Ex-PRESS glaucoma shunt
RATIONALE Neovascular glaucoma (NVG) is one of the most aggressive types of glaucoma, and its abnormal fibrovascular tissue growth on the iris and trabecular meshwork may create difficulties to control the intraocular pressure (IOP) and perform the operation such as trabeculectomy. PATIENT CONCERNS Ex-PRESS glaucoma shunt has been introduced to serve as one alternative operation for glaucoma,...
متن کاملEvaluation of Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma.
PURPOSE To evaluate the intraocular pressure (IOP) control and graft survival after Ex-PRESS mini glaucoma shunt implantation in refractory postpenetrating keratoplasty glaucoma. METHODS The study included postpenetrating keratoplasty glaucoma cases unresponsive to medical antiglaucomatous therapy in whom 15 Ex-PRESS mini glaucoma shunt implantation was carried out. All glaucoma shunt implant...
متن کاملComparison of trabeculectomy with Ex-PRESS shunt implantation in primary-open-angle-glaucoma patients: A retrospective study
PURPOSE To investigate the efficacy of intraocular pressure (IOP) control and medication use over time after trabeculectomy (TRBC) and Ex-PRESS shunt implantation in primary-open-angle-glaucoma (POAG) patients. DESIGN Retrospective case series. PATIENTS AND METHODS A total of 33 unilateral POAG patients were enrolled, and 17 patients received traditional TRBC and 16 patients received Ex-PRE...
متن کامل