In Vitro Accuracy of the Single-Use Hunter TPS Periodontal Probe Considering Material Fatigue and Erroneous Assembly
نویسندگان
چکیده
Repeated measurements of pocket depth (PD), probing attachment level (PAL) and bleeding on probing (BoP) are among the most important diagnostic means for evaluating the status of periodontal health (Listgarten, 1980; Lang et al, 1991; Hefti, 1997). Ideally a blunted probe is gently inserted into the gingival sulcus until the probe tip reaches the most apical extension of the dentogingival epithelium. Numerous experimental studies however have shown that in a clinical situation several parameters may substantially impair the precision and reproducibilty of the measurements. Among them are the probing force (Mombelli and Graf, 1986), the thickness of the probe tip (Attasi et al, 1992), the inflammatory status of the subgingival connective tissue (Spray et al, 1978; Fowler et al, 1982), and the difficulty to introduce the probe tip reproducibly at the identical position and angulation (Pihlström, 1992). The control of the applied probing force is of particular concern, as the terminal position of the probe tip within the periodontal tissues is signifiIn Vitro Accuracy of the Single-Use Hunter TPS Periodontal Probe Considering Material Fatigue and Erroneous Assembly
منابع مشابه
Gingival Thickness Assessment: Visual versus Direct Measurement
Background and Aim: Several methods have been suggested to measure gingival thick-ness. This study aimed to assess the reliability of visual assessment of facial gingival biotype of maxillary and mandibular teeth with or without using a periodontal probe in comparison with direct measurement. Materials and Methods: Sixty-seven healthy patients (25 women and 42 men) with a total of 100 hopele...
متن کاملAccuracy and reproducibility of probe forces during simulated periodontal pocket depth measurements.
AIM The aim of the present study was to measure the accuracy and reproducibility of probe forces in simulated assessments of periodontal pocket depth. The study included experienced and inexperienced examiners and used manual and pressure-sensitive probes. MATERIALS AND METHODS Sixty-one participants were divided into seven groups and asked to probe selected anterior and posterior sites with ...
متن کاملIn-vitro accuracy and reproducibility evaluation of probing depth measurements of selected periodontal probes.
AIM The purpose of the present in vitro study was to measure the accuracy and reproducibility of three periodontal probes. To eliminate environment- or examiner-related probing errors, two aluminum blocks with predrilled holes of varying depths were examined by participants who had been trained in probing before the study. This methodology improved the likelihood that any probing errors identif...
متن کاملEvaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy
Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...
متن کاملCalculation of absorbed dose in lung tissue equivalent and compared it with prediction of a treatment planning system using Collapsed Cone Convolution algorithm
External radiotherapy is used for treatment of various types of cancers. Due to the impossibility of measuring the absorbed dose delivered to different organs during irradiation, treatment planning systems (TPSs) have been utilized for calculation of absorbed dose before a radiotherapy procedure. Thus, the accuracy and precession of the TPS is essential.The aim of this study is investigation of...
متن کامل