Polarization Coherence Tomography ( Pct ) :
نویسنده
چکیده
Polarization Coherence Tomography (PCT): ................................................................1 A Tutorial Introduction ..................................................................................................1 1.
منابع مشابه
On the Performance of Forest Vertical Structure Estimation via Polarization Coherence Tomography
In this paper, we assess potentials and limitations of vertical structure estimation via polarization coherence tomography (PCT) for the processing of multibaseline SAR data, by using simulated data. We discuss the quality of the profile retrieval for natural environment in presence of several distortions as system errors and inaccurate a priori information, by means of simulations.
متن کاملCoherence Based Polarimetric SAR Tomography
Synthetic Aperture Radar (SAR) three dimensional image provides the scene reflectivity along azimuth, range and elevation coordinates. This 3-D image is formed from acquisition of multiple signals from different orbits. Tomographic reconstruction of this image gives the vertical information of the object present in the data. Polarization Coherence Tomography (PCT) is used for estimation of vert...
متن کاملObjective quantification of posterior capsule opacification after cataract surgery, with optical coherence tomography.
PURPOSE To evaluate posterior capsule opacification (PCO) in humans after cataract surgery with intraocular lens (IOL) implantation, by using optical coherence tomography (OCT-1). METHODS Sixty-six eyes with PCO and 20 eyes with a normal posterior capsule were analyzed. A 3-mm-long horizontal scan of the posterior capsule was obtained. Measurements at three points and their average were recor...
متن کاملRelationship between the Lamina Cribrosa, Outer Retina, and Choroidal Thickness as Assessed Using Spectral Domain Optical Coherence Tomography
PURPOSE To evaluate the characteristics and relationship between peripapillary choroidal thickness (pCT), lamina cribrosa thickness (LCT), and peripapillary outer retinal layer thickness (pORT) as determined using spectral domain optical coherence tomography (SD-OCT) enhanced depth imaging (EDI). METHODS In total, 255 participants were included (87 healthy subjects, 87 glaucoma suspects (GS),...
متن کاملStrategies for fast and low-dose laboratory-based phase contrast tomography for microstructural scaffold analysis in tissue engineering
The application of x-ray phase contrast computed tomography (PCT) to the field of tissue engineering is discussed. Specific focus is on the edge illumination PCT method, which can be adapted to weakly coherent x-ray sources, permitting PCT imaging in standard (non-synchrotron) laboratory environments. The method was applied to a prominent research topic in tissue engineering, namely the develop...
متن کامل