Contribution of Ni KLL Auger electrons to the probing depth of the conversion electron yield measurements.
نویسندگان
چکیده
The averaged attenuation length of emitted electrons with the conversion electron yield (CEY) method was evaluated for Ni films with the x-rays below and above the Ni K absorption edge. The evaluated attenuation length was 13.1 nm with the x-rays below the Ni K absorption edge, and it became 24.0 nm with the contribution of Ni KLL Auger electrons that had the attenuation length of 78.1 nm. The probing depth of the CEY measurements are determined both the penetration depth of x-rays and the attenuation length of emitted electrons, and the modification of the probing depth was investigated with the grazing incidence condition. The glancing angle dependence of the CEY was compared with the model calculation, and the probing depth of around 1.6 nm was realized under the total reflection condition. The probing depth was controlled from 1.6 nm to the attenuation length by changing the glancing angle.
منابع مشابه
The probing depth of total electron yield in the sub-keV range: TEY-XAS and X-PEEM
X-ray absorption spectra can be collected in multiple ways, each exhibiting a different probing depth. The total electron yield signal contains contributions from primary, Auger and secondary electrons. We present data on the total electron yield probing depth at core level energies ranging from 77 to 929 eV. By coating materials with chromium overlayers, we find that the maximum probing depth ...
متن کاملEvaluation of the relative biological effectiveness of the Auger electrons produced during gadolinium neutron capture therapy using microdosimetric approach
Determination of the relative biological effectiveness (RBE) of Auger electrons is a challenging task in radiobiology. In this study, we have estimated the RBE of internal conversion (IC) and Auger electrons released during Gadolinium neutron capture reaction (GNCR) by means of biological weighting functions (BWFs) with microdosimetric approach. Regarding the different distribution of Gadoliniu...
متن کاملAbsolute Auger rates, relative intensities and angular distribution for the KLL spectra of Auger electrons from laser-excited sodium
The absolute Auger rates, relative intensities and the angular anisotropy coefficients of Auger electrons have been calculated for the KLL Auger spectra of laser-excited sodium atoms. Where in closed-shell atoms the KLL Auger lines have to be isotropic this is no longer valid for certain Auger transitions in open-shell systems. To study the KLL Auger spectra of 3s → 3p excited sodium atoms we c...
متن کاملEvaluation of the Effects of Different Filters and Helium Bag on the Reduction of Electron Contamination in Photon Beam of Neptun Linac
Introduction: Skin sparing is one of the most desirable characteristics of high energy photon beams. However, the photons emerging from the target of linacs are contaminated by secondary electrons as a result of their interactions with air, collimators, flattening filter and any other objects in their path. This phenomenon tends to increase the skin dose received b...
متن کاملEvaluation of Electron Contamination in Cancer Treatment with Megavoltage Photon Beams: Monte Carlo Study
Background: Megavoltage beams used in radiotherapy are contaminated with secondary electrons. Different parts of linac head and air above patient act as a source of this contamination. This contamination can increase damage to skin and subcutaneous tissue during radiotherapy. Monte Carlo simulation is an accurate method for dose calculation in medical dosimetry and has an important role in opt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2010