Evaluation of the vitek 2 AST-P559 card for detection of oxacillin resistance in Staphylococcus aureus.

نویسندگان

  • Eva Torres
  • Sonia Pérez
  • Rosa Villanueva
  • Germán Bou
چکیده

Staphylococcus aureus strains with resistance to methicillin or oxacillin (MRSA) represent one of the main nosocomial pathogens at present. MRSA infections are clearly associated with higher mortality and economic cost than those caused by methicillin-susceptible S. aureus (1). In Spain, the prevalence of methicillin resistance among S. aureus isolates has increased since the 1990s and in some cases has now reached levels higher than 30% (2). Rapid and accurate detection of MRSA strains in hospital as well as community settings is imperative. The performance of cefoxitin either as a disk or as a supplement in agar medium for the detection of MRSA has been confirmed extensively (6, 7). Also, cefoxitin-based screening broth proved to be more sensitive and rapid than oxacillinbased broth (3). Recently, a new Vitek card (AST P549) for determining susceptibility of S. aureus to oxacillin has been reported (5). The Vitek 2 AST-P559 card (bioMérieux) incorporates specific antimicrobial agents to test susceptibility and also includes the determination of oxacillin MICs as well as screening for cefoxitin (6 g/ml). The main advantage of the card is its promptness in detecting methicillin resistance, as it is possible to interpret the results of a cefoxitin screen after 4 h of card inoculation. However, final confirmation is done after 12 h upon reading the oxacillin MICs as well as the cefoxitin screen well and according to the manufacturer s instructions. The Vitek 2 AST-P559 card cannot be manually read, so interpretive information must be derived from the software interpretation. A total of 301 S. aureus strains were evaluated (51 mecA negative and 250 mecA positive as determined by PCR). S. aureus ATCC 29213 was used as a negative control. Molecular typing of the X region of the spa gene was done with the 250 mecA-positive isolates (4), and these were then grouped into a spa clonal complex (BURST.Ridom StaphType software), with 4 types more prevalent than the others (t02, 23.6%; t18, 22%; t67, 17.6%; and t12, 16.3%). Overall results are shown in Table 1. Three out of 250 isolates yielded a negative result by the cefoxitin screening methods as well as yielding an oxacillin MIC of 2. However, when these isolates were preincubated for 24 h in BBL CHROMagar MRSA medium (BD Diagnostics, Sparks, MD), which includes 6 g/ml of cefoxitin, and the assay was repeated, they yielded a positive result with both antibiotics, therefore suggesting that the existence of subpopulations heteroresistant to oxacillin may cause a false-negative result with the Vitek 2 card. All mecA-positive isolates yielded a positive result with the cefoxitin screening (and also yielded an oxacillin MIC of 4 g/ml) and showed positive PBP 2a agglutination with the Slidex MRSA detection kit (bioMérieux). Regarding specificity, all mecA-negative S. aureus strains were negative by the cefoxitin screening method and also yielded an oxacillin MIC of 2 g/ml. However, PBP 2a agglutination yielded three false-positive results (96% specificity). Considering the results from these three isolates at preincubation time with the cefoxitin agar plate (false negative), the overall results of this study with the AST-P559 card showed sensitivity and specificity of 98.8% and 100%, respectively. The positive and negative predictive values were 100% and 94%, respectively. However, the values for all parameters increased to 100% when the three strains were analyzed after induction of the mecA gene product with cefoxitin. The main advantage of the AST-P559 card is the incorporation of two tests to provide simultaneous determination of oxacillin MICs as well as cefoxitin screening. Several studies (6, 7) have shown that cefoxitin is a better predictor of the presence of mecA than oxacillin, and, indeed, Velasco et al. (7) reported an increase of 2% in sensitivity to detect mecA when the cefoxitin screening test was used in addition to the oxacillin MIC. For these reasons, the simultaneous presence of two tests (oxacillin MIC and cefoxitin screening) in the same card may offer a noticeable advantage for detection of some mecA-negative S. aureus isolates which are identified by cefoxitin screening rather than oxacillin MIC. In addition, information about susceptibility to antibiotics against gram-positive microorganisms is provided by this card, which offers an undoubted advantage with respect to chromogenic agars, agglutination latex, or molecular techniques, since they only detect the marker of resistance to oxacillin. In addition to that, the possibility of diagnosis of an MRSA infection in 4 h (by the software interpretation of the cefoxitin screening) will make the use of this automated method very attractive for clinical microbiology laboratories worldwide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of new Vitek 2 card and disk diffusion method for determining susceptibility of Staphylococcus aureus to oxacillin.

Detection of methicillin resistance in Staphylococcus aureus is a challenge, especially low-level resistance, which is often misdiagnosed. The aim of this study was to compare the diagnostic accuracies of the automated Vitek 2 system and disk diffusion tests, using cefoxitin and moxalactam, for the detection of methicillin resistance in S. aureus strains. Four sets of genotypically diverse isol...

متن کامل

Performance of MicroScan WalkAway and Vitek 2 for detection of oxacillin resistance in a set of methicillin-resistant Staphylococcus aureus isolates with diverse genetic backgrounds.

Of 104 genotypically diverse methicillin-resistant Staphylococcus aureus (MRSA) isolates tested with the MicroScan WalkAway (Pos MIC 24 panel) and Vitek 2 (AST-P549 card) systems, 7 and 6 isolates, respectively, showed an oxacillin MIC of < or =2mg/liter. Most of these MRSA isolates were community acquired. However, if the cefoxitin screen of AST-P549 was also considered, MRSA detection failed ...

متن کامل

Evaluation of differential inoculum disk diffusion method and Vitek GPS-SA card for detection of oxacillin-resistant staphylococci.

This study was conducted in order to compare the accuracy of detection of oxacillin-resistant staphylococci, defined by microdilution MICs, population analyses, and mec gene hybridization, with the Vitek GPS-SA Susceptibility Card with that of the standard inoculum (10(7) CFU) and high-inoculum (10(9) CFU) disk diffusion tests. By the standard inoculum disk diffusion test, 10 of 67 (15%) isolat...

متن کامل

Comparison of the Vitek gram-positive susceptibility 106 card, the MRSA-Screen latex agglutination test, and mecA analysis for detecting oxacillin resistance in a geographically diverse collection of clinical isolates of coagulase-negative staphylococci.

The Vitek automated susceptibility testing system with a modified gram-positive susceptibility (GPS) 106 card (bioMerieux Vitek, Inc., Hazelwood. Mo.) and a rapid slide latex agglutination test (MRSA-Screen test; Denka Seiken Co., Ltd., Tokyo, Japan) were evaluated for their abilities to detect oxacillin resistance in coagulase-negative staphylococci (CoNS). The reference broth microdilution me...

متن کامل

Comparison of ATB staph, rapid ATB staph, Vitek, and E-test methods for detection of oxacillin heteroresistance in staphylococci possessing mecA.

The performance characteristics of the E-test (AB Biodisk, Solna, Sweden), the ATB Staph, the Rapid ATB Staph, and the Vitek GPS-503 card (bioMérieux, La Balme Les Grottes, France) methods for the detection of oxacillin resistance in a collection of staphylococci with a high proportion of troublesome strains were evaluated. Sixty-four Staphylococcus aureus strains and 76 coagulase-negative stap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 46 12  شماره 

صفحات  -

تاریخ انتشار 2008