Can bone apposition predict the retention force of a femoral stem? An experimental weight-bearing hip-implant model in goats

نویسندگان

  • Knut Harboe
  • Christian Lycke Ellingsen
  • Einar Sudmann
  • Nils Roar Gjerdet
  • Kjetil Søreide
  • Kari Indrekvam
چکیده

BACKGROUND The increasing incidence of prosthesis revision surgery in the Western world has led to an increased focus on the capacity for stem removal. We previously reported on a femoral stem implanted in goats with an approximate 15% reduction in retention force by drilling longitudinally orientated grooves on the side of the stem. In this current study, we aimed to histologically evaluate the bony apposition towards this stem and correlate this apposition with the pullout force. METHODS We analyzed the femora of 22 goats after stem removal. All stems remained in place for 6 months, and the goats were allowed regular loading of the hip during this time. For histological evaluation, all femora were immersed in EDTA and decalcified until sufficiently soft for standard technique preparation. We evaluated bone apposition, the presence of foreign particle debris and other factors. The apposition was evaluated with a scoring system based on semi-quantitative bone apposition in four quadrants. Kappa statistics were calculated for the score. We correlated the retention force with the amount of bone apposition. RESULTS The stem drilling was the only significant factor influencing the retention force (p = 0.020). The bone apposition Kappa score comparing poor and good apposition scores was fair (κ = 0.4, 95% CI 0.00-0.88). Signs of foreign body reaction were noted in 5 of 22 goats. CONCLUSIONS Based on the current findings in an experimental goat model, it appears that the effect of drilling tissue/bone out of the longitudinal grooves has a more significant impact on the retention force required to remove the stem than the amount of bone apposition outside the stem grooves. This observation may be further explored in the research of stem designs that are potentially easier to remove.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model

BACKGROUND Since the introduction of uncemented hip implants, there has been a search for the best surface coating to enhance bone apposition in order to improve retention. The surface coating of the different stems varies between products. The aim was to assess the retention force and bone adaption in two differently coated stems in a weight-bearing goat model. MATERIALS AND METHODS Hydroxya...

متن کامل

The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.

This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...

متن کامل

Subchondral Insufficiency Fracture of the Femoral Head Treated with Core Decompression and Bone Void Filler Support

Subchondral insufficiency fracture of the femoral head (SIFFH) is characterized by acute onset hip pain without overt trauma. It appears as a low intensity band with bone marrow edema on T1-weighted MRI. The most common course of treatment is protected weight bearing for a period of several weeks. Total hip arthroplasty (THA) has been commonly used if the patient does not respond to the initial...

متن کامل

تأثیر تمرینات ورزشی در آب بر تراکم استخوان زنان پری منوپوز

Introduction: Exercises are effective in bone density in different areas of the body when they can increase the mechanical load or dynamic pressure in those areas. Therefore, the aim of this study was to investigate the effect of exercises in water on bone density of premenopausal women. Methods: This semi-experimental study was of pretest-posttest design. Twenty premenopausal women, between...

متن کامل

Defining the impaction frequency and threshold force required for femoral impaction grafting in revision hip arthroplasty

BACKGROUND AND PURPOSE The two most common complications of femoral impaction bone grafting are femoral fracture and massive implant subsidence. We investigated fracture forces and implant subsidence rates in embalmed human femurs undergoing impaction grafting. The study consisted of two arms, the first examining the force at which femoral fracture occurs in the embalmed human femur, and the se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015