Water use of a multigenotype poplar short‐rotation coppice from tree to stand scale

نویسندگان

  • Jasper Bloemen
  • Régis Fichot
  • Joanna A. Horemans
  • Laura S. Broeckx
  • Melanie S. Verlinden
  • Terenzio Zenone
  • Reinhart Ceulemans
چکیده

Short-rotation coppice (SRC) has great potential for supplying biomass-based heat and energy, but little is known about SRC's ecological footprint, particularly its impact on the water cycle. To this end, we quantified the water use of a commercial scale poplar (Populus) SRC plantation in East Flanders (Belgium) at tree and stand level, focusing primarily on the transpiration component. First, we used the AquaCrop model and eddy covariance flux data to analyse the different components of the stand-level water balance for one entire growing season. Transpiration represented 59% of evapotranspiration (ET) at stand scale over the whole year. Measured ET and modelled ET were lower as compared to the ET of reference grassland, suggesting that the SRC only used a limited amount of water. Secondly, we compared leaf area scaled and sapwood area scaled sap flow (Fs) measurements on individual plants vs. stand scale eddy covariance flux data during a 39-day intensive field campaign in late summer 2011. Daily stem diameter variation (∆D) was monitored simultaneously with Fs to understand water use strategies for three poplar genotypes. Canopy transpiration based on sapwood area or leaf area scaling was 43.5 and 50.3 mm, respectively, and accounted for 74%, respectively, 86%, of total ecosystem ET measured during the intensive field campaign. Besides differences in growth, the significant intergenotypic differences in daily ∆D (due to stem shrinkage and swelling) suggested different water use strategies among the three genotypes which were confirmed by the sap flow measurements. Future studies on the prediction of SRC water use, or efforts to enhance the biomass yield of SRC genotypes, should consider intergenotypic differences in transpiration water losses at tree level as well as the SRC water balance at stand level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harvesting Systems and Costs for Short Rotation Poplar

The objective of this review is to compare the cost of coppice and longer rotation poplar harvesting technology. Harvesting technology for short rotation poplar has evolved over the years to address both coppice harvest and single-stem harvest systems. Two potential approaches for coppice harvesting are modified forage harvesters and modified mulcher-balers. Both of these systems effectively ha...

متن کامل

Can we use short rotation coppice poplar for sugar based biorefinery feedstock? Bioconversion of 2-year-old poplar grown as short rotation coppice

BACKGROUND Feedstock cost is a substantial barrier to the commercialization of lignocellulosic biorefineries. Poplar grown using a short rotation coppice (SRC) system has the potential to provide a low-cost feedstock and economically viable sugar yields for fuels and chemicals production. In the coppice management regime, poplars are harvested after 2 years' growth to develop the root system an...

متن کامل

Evaluation of Indirect Measurement Method of Seasonal Patterns of Leaf Area Index in a High-density Short Rotation Coppice Culture of Poplar

TRIPATHI ABHISHEK M., FISCHER MILAN, ORSÁG MATĚJ, MAREK MICHAL V., ŽALUD ZDENĚK, TRNKA MIREK. 2016. Evaluation of Indirect Measurement Method of Seasonal Patterns of Leaf Area Index in a High-Density Short Rotation Coppice Culture of Poplar. Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis, 64(2): 549–556. Leaf area index (LAI) is an important determinant of biomass produc...

متن کامل

Can the agricultural AquaCrop model simulate water use and yield of a poplar short‐rotation coppice?

We calibrated and evaluated the agricultural model AquaCrop for the simulation of water use and yield of a short-rotation coppice (SRC) plantation with poplar (Populus) in East Flanders (Belgium) during the second and the third rotation (first 2 years only). Differences in crop development and growth during the course of the rotations were taken into account during the model calibration. Overal...

متن کامل

Water use efficiency of short-rotation Salix viminalis at leaf, tree and stand scales.

Fluxes of water and carbon dioxide from short-rotation Salix viminalis L. were measured at leaf, tree and stand scales using porometer, chamber and micrometeorological techniques, respectively. At all three scales, instantaneous water use efficiency exhibited a similar dependence on vapor pressure deficit (deltae) with values of 21, 13 and 10 g CO(2) per kg H(2)O for deltae of 0.5, 1.0 and 1.5 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017