When a snapped sternal wire stabbed the aorta.

نویسندگان

  • Kazuhito Imanaka
  • Toshihisa Asakura
  • Hideaki Yamabi
چکیده

Fig. 1. This 44-year-old male, who had a history of aortic root replacement for acute aortic dissection 9 years ago, suffered impending rupture of dissecting aneurysm in the distal aortic arch. He underwent replacement of the aortic arch and stent graft implantation into the descending aorta. Two weeks later, the sternum was dehisced, but the cut end of the snapped wire was remote from the aorta. Surgical revision of the sternum was not performed because of his delayed convalescence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulling the finger off disrupts agency, embodiment and peripersonal space.

For this experiment a visual illusion was created in which the participant's finger looked and felt as though it was being stretched to twice its normal length until it snapped and the tip came off. It was then stabbed with virtual weapons while skin conductance was measured. Sometimes the fingertip moved under the participant's own control and sometimes it moved independently. Curiously, detac...

متن کامل

Right ventricular laceration caused by an intact sternal wire: a rare complication of median sternotomy.

A 68-year-old man underwent an intervention for acute aortic dissection. After extubation, he was treated with non-invasive ventilation because of respiratory distress. On postoperative day 7, the patient suffered severe hypotension, tachycardia and a raised central venous pressure. The emergent resternotomy revealed that the lower sternal wire had led to a right ventricle laceration (Figs 1 an...

متن کامل

Traumatic Bilateral Pneumothoraces due to Sternal Wire Migration

Sternal wound complications after cardiac surgery are associated with increased morbidity and mortality. Wire migrations associated with sternal dehiscence can lead to catastrophic haemorrhage unless intervened in time. We present a case of sternal wire migration causing bilateral pneumothoraces.

متن کامل

Reduction in deep sternal wound infection with use of a peristernal cable-tie closure system: a retrospective case series

BACKGROUND Deep sternal wound infections are a rare but serious complication after median sternotomy. We evaluated the incidence of deep sternal wound infection associated with two techniques for sternal closure. METHODS In this retrospective case series, we recorded the method of sternal closure in consecutive patients undergoing a variety of cardiothoracic surgical procedures. Sternal closu...

متن کامل

Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

BACKGROUND Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2008