Use of multi-spectral MR data to generate an attenuation map for application to PET/MR hybrid imaging
نویسندگان
چکیده
Introduction Intensive research is currently ongoing to develop hybrid PET/MR imaging systems. A handful of small animal studies have been published and the first human brain PET/MR images were recently obtained [1]. However, to generate quantitatively accurate PET images, gamma ray attenuation must be corrected. In PET/CT, this is done by taking advantage of the electron density information obtained from the CT data in order to generate an attenuation map. Unfortunately, MR images are not clearly related to electron density, so this method cannot be applied to the PET/MR platform. An alternative approach is to determine the position of anatomical structures from the MR images and then to assign these structures known attenuation coefficients. Thus far, this technique has only been attempted using single-spectral MR and has only been applied to the brain [2]. In the present work, we used canine multi-spectral MR data to generate abdominal and thoracic attenuation maps for PET. Methods Three adult mongrel canines were anesthetized and immobilized on a moveable platform. The canines were subsequently imaged using CT (Siemens Symbia T6 6-slice) and MR (Siemens Avanto 1.5T). Four MR data sets were acquired: T1-weighted (w), T2-w, proton density (PD) w, and water-suppressed (WS) PDw. The CT data were converted to mono-energetic (511 keV) attenuation maps and registered to the MR data sets. Four tissue types (hard tissue, soft tissue, lung, and air) were segmented from each MR data set using a k-means algorithm [3] (6 clusters) in order to generate mono-energetic attenuation maps. Further, clusters from various combinations of individual MR data sets were merged using a probabilistic model to yield attenuation maps. Each MR-derived attenuation map was compared to the CT-derived attenuation map by comparing their respective radon transforms on a pixel-by-pixel basis. Results Figure 1 depicts a visual comparison of the attenuation maps generated via CT versus multi-spectral MR. An example of a quantitative comparison via the Radon transform is presented in Figure 2. Finally, Table 1 summarizes the quantitative comparisons. For abdominal slices, single and multi-spectral MR derived attenuation maps were of comparable accuracy; for thoracic slices, multi-spectral techniques yielded superior results. In general, it was more challenging to obtain attenuation maps for thoracic slices than abdominal slices. Discussion We have demonstrated that multi-spectral MR data can yield better PET attenuation maps than single-spectral data, at least at the thoracic level. This supports prior evidence that multi-spectral MR can improve segmentation algorithm performance [4]. The best combinations of MR data were T2w & PDw & WSPDw for abdominal slices and T1w & PDw & WSPDw for thoracic slices (as judged by the highest R and proximity of the line-of-best-fit to Y=X). We found that, in general, PDw was most helpful for identifying soft tissue and lung while WSPDw aided greatly in edge and marrow detection. Segmentation was weak for bones and cartilage, but the use of alternate MR sequences may improve performance (e.g. ultra-short TE imaging [5]). This work clearly demonstrates that using multi-spectral MR data to generate attenuation maps is a feasible approach for the purposes of PET correction in PET/MR systems. References [1] Schlemmer H. et al. (2008) Radiolog 248(3) 1028 – 1035. [2] Zaidi H. et al. (2003) Med. Phys. 30(5) 937 – 948. [3] Hartigan J. et al. (1979) Appl. Stat. 28 100 – 108. [4] He R. (2005) Ann. Biomed. Eng. 33 1439 – 1448. [5] Du J. et al. (2008) Proc. Int. Soc. Mag. Reson. Med. 16 332. MRI parameters Line of best fit R
منابع مشابه
Recent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملComparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction
Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملMagnetic resonance-based attenuation correction for PET/MR hybrid imaging using continuous valued attenuation maps.
OBJECTIVES Attenuation correction of positron emission tomographic (PET) data is critical in providing accurate and quantitative PET volumes. Deriving an attenuation map (μ-map) from magnetic resonance (MR) volumes is a challenge in PET/MR hybrid imaging. The difficulty lies in differentiating cortical bone from air from standard MR sequences because both these classes yield little to no MR sig...
متن کاملWhole-body hybrid imaging concept for the integration of PET/MR into radiation therapy treatment planning.
Modern radiation therapy (RT) treatment planning is based on multimodality imaging. With the recent availability of whole-body PET/MR hybrid imaging new opportunities arise to improve target volume delineation in RT treatment planning. This, however, requires dedicated RT equipment for reproducible patient positioning on the PET/MR system, which has to be compatible with MR and PET imaging. A p...
متن کامل