Τhe first implementation of IMRT technique for head & neck and prostate cancer patients in public sector in Greece: feasibility, treatment planning and dose delivery verification using the delta4PT Pre-Treatment volumetric quality assurance system
نویسندگان
چکیده
Purpose: Intensity Modulated Radiation Therapy (IMRT) is nowadays the treatment of choice, in terms of technique, for either head & neck or prostate cancer. With this paper, we are sharing our experience for the first inplementation of IMRT planning in the public sector in Greece, and especially in the Aretaieion University Hospital of Athens. Methods: From May 2013 until January 2014 four prostate and four head & neck cancer patients were evaluated in the present study. We used the ONCENTRA IMRT treatment planning with a step and shoot technique in a SIEMENS ONCORE Linac. The dose verification method used was based on the delta4PT Pre-Treatment volumetric quality assurance system, by Scadidos. Results: In all cases, the Relative Standard Deviation between the prescribed and the calculated average dose received by the target volume was less than 5%, while the γ-index was more than 90%. The acute toxicity was low and equivalent to published data with IMRT technique. Conclusion: In conclusion, the first implementation of IMRT technique in the Medical School of Athens was feasible and safe as well as in terms of dose verification. The IMRT technique is already in clinical use and further results with long term radiation induced toxicity will be reported.
منابع مشابه
Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT
Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملA Feasibility Study of IMRT of Lung Cancer Using Gafchromic EBT3 Film
Background: Intensity modulated radiation therapy (IMRT) is an advanced method for delivery of three dimensional therapies, which provides optimal dose distribution with giving multiple nonuniform fluency to the patient. The complex dose distribution of IMRT should be checked to ensure that the accurate dose is delivered. Today, film dosimetry is a powerful tool for radiotherapy treatment Quali...
متن کاملDose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer
Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...
متن کاملRadiation treatment planning for prostate cancer: A new dosimetric comparison of five and seven fields IMRT plans
Background: To compare the dosimetric coverage of the planning target volume (PTV) and the dose delivered to the main Organs at Risk (OARs) in 5 and 7-field techniques of Intensity Modulated Radiation Therapy (IMRT) in patients with local prostate cancer. Materials and Methods: Twelve patients with local prostate cancer underwent 5 and 7-field IMRT planning. The delivery of IMRT was carried out...
متن کامل