Lack of increased signal intensity in the dentate nucleus after repeated administration of a macrocyclic contrast agent in multiple sclerosis

نویسندگان

  • Philipp Eisele
  • Angelika Alonso
  • Kristina Szabo
  • Anne Ebert
  • Melissa Ong
  • Stefan O. Schoenberg
  • Achim Gass
چکیده

Recently, several studies reported increased signal intensity (SI) in the dentate nucleus (DN) after repeated application of gadolinium-based contrast agents (GBCAs), suggesting a deposition of gadolinium in this location. Patients with relapsing-remitting multiple sclerosis (RRMS) frequently show increased permeability of the blood-brain barrier as part of the inflammatory process in the brain parenchyma, which theoretically might increase the risk of gadolinium deposition. In this retrospective study, we investigated a possible increasing SI in the DN after repeated administrations of the macrocyclic contrast agent gadoterate meglumine.Forty-one RRMS patients (33 women, mean age 38 years) with at least 6 prior gadolinium-enhanced examinations (single dose gadoterate meglumine) were identified. A total of 279 unenhanced T1-weighted examinations were analyzed.SI ratio differences did not differ between the first and last MRI examination, neither for the DN-to-pons ratio (P = 0.594) nor for the DN-to-cerebellum ratio (P = 0.847). There was no correlation between the mean DN-to-pons, or between the mean DN-to-cerebellum SI ratio and the number of MRI examinations (P = 0.848 and 0.891), disease duration (P = 0.676 and 0.985), and expanded disability status scale (EDSS) (P = 0.639 and 0.945).We found no signal increases in the DN after a minimum of 6 injections of the macrocyclic GBCA gadoterate meglumine in RRMS patients. This warrants further investigations in regard to the true pathophysiologic basis of intracerebral gadolinium deposition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retention of Gadolinium-Based Contrast Agents in Multiple Sclerosis: Retrospective Analysis of an 18-Year Longitudinal Study.

BACKGROUND AND PURPOSE Gadolinium-based contrast agents have been associated with lasting high T1-weighted signal intensity in the dentate nucleus and globus pallidus, with histopathologically confirmed gadolinium retention. We aimed to longitudinally investigate the relationship of multiple gadolinium-based contrast agent administrations to the Signal Intensity Index in the dentate nucleus and...

متن کامل

Gadopentetate but not gadobutrol accumulates in the dentate nucleus of multiple sclerosis patients.

BACKGROUND Previous studies have postulated an association between dentate nucleus T1 hyperintensity and multiple sclerosis (MS)-related progressive neurodegeneration. Therefore, MS patients have been excluded from most studies investigating brain deposition of gadolinium-based contrast agents (GBCAs). OBJECTIVE To study the hypothesis that dentate nucleus T1 hyperintensity in MS patients is ...

متن کامل

Macrocyclic Versus Linear Gadolinium Chelates.

T he article “High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1weighted images: evaluation of the macrocyclic gadolinium-based contrast agent gadobutrol” by Radbruch et al provides critical new information regarding gadolinium deposition in the dentate nucleus. The conclusion, from a study of 30 patients, is that no signal intensity increase is seen with gadobutr...

متن کامل

The presence of the gadolinium-based contrast agent depositions in the brain and symptoms of gadolinium neurotoxicity - A systematic review

BACKGROUND AND PURPOSE Gadolinium based contrast agents (GBCAs) are widely used in magnetic resonance imaging, but recently, high signal intensity in the cerebellum structures was reported after repeated administrations of contrast- enhanced magnetic resonance images. The aim of this systematic review was to investigate the association between increased signal intensity in the dentate nucleus a...

متن کامل

Up to 52 administrations of macrocyclic ionic MR contrast agent are not associated with intracranial gadolinium deposition: Multifactorial analysis in 385 patients

PURPOSE To determine whether multiple repeated administrations of gadolinium-based macrocyclic ionic MR contrast agent (MICA) are associated with intracranial gadolinium deposition and identify the predisposing factors for deposition in various clinical situations. MATERIALS AND METHODS In this institutional review board-approved retrospective study, 385 consecutive patients who underwent MIC...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016