Does the type of prosthesis influence the incidence of permanent pacemaker implantation following isolated aortic valve replacement.

نویسندگان

  • Maqsood M Elahi
  • Khalid A Osman
  • Manoj Bhandari
  • Ramana Rao V Dhannapuneni
چکیده

BACKGROUND The incidence of conduction disorders requiring permanent pacing (PPM) in patients operated on for aortic valve replacement (AVR) has been reported to be 5.7%. However, perioperative risk predictors for PPM following AVR are not well characterized and debate exists regarding selection of the prosthesis-type most likely to minimize this incidence. The aim of the study was to assess whether the type of the prosthesis used influences the prevalence of PPM following aortic valve replacement. METHODS A total of 782 consecutive patients with predominant aortic stenosis accepted for isolated non-emergent AVR were studied over a 3 year period; of which 305 patients (Group A) received mechanical prostheses, 335 received stented tissue prostheses (Group B), and the remaining 142 received stentless tissue valves (Group C). A stepwise logistic regression analysis was used to identify the independent predictors for PPM and statistical significance was accepted at a level of P < .05. RESULTS Univariate and multivariate analyses showed a significant relationship between the preoperative factors (poor ejection fraction < 35%; P < .001), left atrial enlargement (LAE; P < .001) and left bundle branch block (LBBB; P < .001), the perioperative variables (bypass time > 100 minutes with x-clamp time > 70 minutes; P < .001) and the incidence of PPM. CONCLUSIONS The proposed predictive model correlated highly with actual pacemaker use, suggesting that the requirement for PPM results from either operative trauma or increased ischemic burden and the incidence of PPM is independent of prosthesis-type implanted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

In patients undergoing aortic valve replacement, what factors predict the requirement for permanent pacemaker implantation?

A best evidence topic in cardiac surgery was written according to a structured protocol. The question was to determine what preoperative, perioperative and postoperative factors influence the requirement for permanent pacemaker (PPM) implantation postisolated aortic valve replacement (AVR). Transcatheter aortic valve intervention was not included in this analysis. Using the reported search meth...

متن کامل

Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation.

INTRODUCTION AND OBJECTIVES Conduction disturbances often occur after CoreValve transcatheter aortic valve implantation. The aim was to analyze which cardiac conduction changes occur in patients with aortic stenosis treated with this type of prosthesis. METHODS A total of 181 patients with severe aortic stenosis treated with this prosthesis and studied by electrocardiography between April 200...

متن کامل

Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

BACKGROUND Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pace...

متن کامل

Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis.

BACKGROUND Previous reports have suggested the occurrence of cardiac conduction disorders and permanent pacemaker (PPM) requirement after transcatheter aortic valve implantation (TAVI). Based on a single-center experience, we aim to assess the incidence of postprocedural conduction disorders, need for PPM, and its determinants after TAVI with a self-expanding bioprosthesis. METHODS From Augus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The heart surgery forum

دوره 8 6  شماره 

صفحات  -

تاریخ انتشار 2005