Reproducibility of tumor blood flow quantification with 15O-water PET.

نویسندگان

  • Martin A Lodge
  • Heather A Jacene
  • Roberto Pili
  • Richard L Wahl
چکیده

UNLABELLED Noninvasive methods for quantifying tumor blood flow (TBF) have a potentially important role in the field of drug development. (15)O-water PET has been used in several studies aimed at monitoring response to novel treatments. Assessing the significance of changes in TBF requires knowledge of the reproducibility of the technique. This article quantifies the reproducibility of the (15)O-water technique for TBF applications. METHODS A total of 43 pairs of replicate (15)O-water studies were performed on 23 different patients with cancer. TBF was estimated using a standard, single-compartment model, and the replicate data were used to assess the reproducibility of the method. RESULTS The magnitude of the differences between replicate flow measurements was found to be proportional to their means. TBF was measured with a within-subject coefficient of variation of 13.4% and a repeatability of 37.1%. The volume of distribution was measured with a within-subject coefficient of variation of 8.6% and a repeatability of 24.0%. CONCLUSION (15)O-water PET can be used to measure TBF with a reproducibility that is consistent with other applications of the technique. The short half-life of the isotope permits multiple replicate studies to be performed during the same imaging session, allowing the reproducibility of the average flow estimate to be adapted to the required task. (15)O-water PET is a powerful and robust tool for TBF quantification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow.

UNLABELLED PET molecular imaging of 15O-labeled water is the gold standard for measuring blood flow in humans. However, this requires an on-site cyclotron to produce the short-lived 15O tracer, which is cost-prohibitive for most clinical PET centers. The purpose of this study was to determine if the early uptake of 18F-FDG could be used to measure regional blood flow in tumors in the absence of...

متن کامل

Reproducibility of measurements of regional myocardial blood flow in a model of coronary artery disease: Comparison of H215O and 13NH3 PET techniques.

UNLABELLED PET absolute myocardial blood flow (MBF) with H(2)15O and 13NH3 are widely used in clinical and research settings. However, their reproducibility with a 16-myocardial segment model has not been examined in chronic coronary artery disease (CAD). We examined the short-term reproducibility of PET H(2)15O MBF and PET 13NH3 MBF in an animal model of chronic CAD. METHODS Twelve swine (me...

متن کامل

Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.

UNLABELLED Regional myocardial blood flow (MBF) can be measured with 15O-water and PET using the 1-tissue-compartment model with perfusable tissue fraction, which provides an MBF value that is free from the partial-volume effect. Studies with 15O-water have several advantages, such as the ability to repeat a scan. However, because of the short scanning time and the small distribution volume of ...

متن کامل

PET/CT scanning with 3D acquisition is feasible for quantifying myocardial blood flow when diagnosing coronary artery disease

BACKGROUND The quantification of myocardial blood flow (MBF) and coronary flow reserve (CFR) are useful approaches for evaluating the functional severity of coronary artery disease (CAD). 15O-water positron emission tomography (PET) is considered the gold standard method for MBF quantification. However, MBF measurements in 15O-water PET with three-dimensional (3D) data acquisition, attenuation ...

متن کامل

Reproducibility of tumor perfusion measurements using 15O-labeled water and PET.

UNLABELLED PET and 15O-labeled water (H215O) can be used to noninvasively monitor tumor perfusion. This allows evaluation of the direct target of antiangiogenic drugs, that is, tumor vasculature. Because these drugs often result in consolidation rather than regression of the tumor mass, a change in perfusion might be a more sensitive way to evaluate response than are indirect size measures on a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 49 10  شماره 

صفحات  -

تاریخ انتشار 2008