The reliability and concurrent validity of scapular plane shoulder elevation measurements using a digital inclinometer and goniometer.

نویسندگان

  • Morey J Kolber
  • Cydne Fuller
  • Jessica Marshall
  • Amanda Wright
  • William J Hanney
چکیده

This study investigated the reliability and concurrent validity of active shoulder elevation in the scapular plane (scaption) using a digital inclinometer and goniometer. Two investigators used a goniometer and digital inclinometer to measure scaption on 30 asymptomatic participants in a blinded repeated measures design. Good reliability was present with intraclass correlation coefficients (ICCs) for intrarater reliability of goniometry = 0.87, intrarater digital inclinometry = 0.88, interrater goniometry = 0.92, and interrater digital inclinometry = 0.89. The minimal detectable change (MDC95) for the interrater analysis indicated that a change equal to or greater than 8 degrees for goniometry and 9 degrees for inclinometry is required to be 95% certain that the change is not due to intertrial variability or measurement error. The concurrent validity between goniometry and digital inclinometry was excellent with an ICC value of 0.94 for both raters. The 95% limits of agreement suggest that the difference between these two measurement instruments can be expected to vary by up to ±11 degrees. The results support the interchangeable use of goniometry and digital inclinometer for measuring scaption. Clinicians and researchers should consider the MDC values presented when interpreting change during subsequent measurement sessions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a Digital Inclinometer to Assess Scapular Upward Rotation: a Reliability and Validity Study

Proposed New Method: A Pro 360 digital inclinometer (Macklanburg Duncan, Oklahoma City, OK) was used for 2-D static measurements of scapular upward rotation during humeral elevation. The instrument was modified by adding two wooden locator rods to its inferior surface. These rods had Y shaped ends, which were placed over the root of the scapular spine and the posterolateral acromion during each...

متن کامل

The Reliability and Concurrent Validity of Digital Inclinometer, Smartphone Applications, and the Cervical Range of Motion Device for Measuring the Cervical Range of Motion

Objectives: Changes in the Range of Motion (ROM) are essential criteria in determining the severity of spinal disorders and could be effective in predicting pain progression. Instruments to measure the ROM are costly and unavailable in most therapy settings. While there is a tendency in therapists to use their smartphones instead, there is no report to measure the suitability of smartphones to ...

متن کامل

Interrater and Intrarater Reliability and Validity of 3 Measurement Methods for Shoulder-Position Sense.

CONTEXT Joint-position sense (JPS) plays a critical role in the stability of shoulder joint. Restoration of JPS is essential to improve rehabilitation outcomes in individuals with shoulder injury. However, the number of affordable and reliable shoulder-JPS measurement methods for everyday clinical practice is limited. OBJECTIVE To estimate reliability and validity of 3 simple shoulder-JPS mea...

متن کامل

Scapular Position and Orientation during Abduction, Flexion and Scapular Plane Elevation Phase

Objectives: The purpose of this study was to compare scapular kinematics during elevation phase of abduction, flexion, and scapular plane elevation phase between fifteen persons with shoulder impingement syndrome (SIS) and thirteen persons without it. Methods: Values of scapular kinematics include scapular superior and lateral translations, upward rotation, external rotation, and posterior t...

متن کامل

The comparison of acromiohumeral distance and scapular dyskinesis prevalence in females with and without rounded shoulder posture

Background: Altered scapular kinematics in individuals with rounded shoulder posture (RSP) may affect acromiohumeral distance (AHD). The purpose of this study was to compare AHD and scapular dyskinesis prevalence in individuals with and without RSP.    Methods: A total of 44 women (RSP, n=21; control, n=23) participated in the study. RSP was assessed by measuring acromion to table distance (AT...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiotherapy theory and practice

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2012