Variability in monthly serum bicarbonate measures in hemodialysis patients: a cohort study
نویسندگان
چکیده
BACKGROUND Some nephrologists have advocated an individualized approach to the prescription of bicarbonate hemodialysis. However, the utility of monthly serum bicarbonate levels for guiding and evaluating such treatment decisions has not been evaluated. We sought to define the variability of these measurements and to determine factors that are associated with month-to-month variability in pre-dialysis serum bicarbonate. METHODS We examined the monthly variability in serum bicarbonate measurements among 181 hemodialysis patients admitted to a free-standing dialysis unit in the Bronx, NY from 1/1/2008-6/30/2012. All patients were treated with a uniform bicarbonate dialysis prescription (bicarbonate 35 mEq/L, acetate 8 mEq/L). Pre-dialysis serum bicarbonate values were obtained from monthly laboratory reports. Month-to-month variability was defined using a rolling measurement for each time point. RESULTS Only 34 % of high serum bicarbonate values (>26 mEq/L) remained high in the subsequent month, whereas 60 % converted to normal (22-26 mEq/L). Of all low values (<22 mEq/L), 41 % were normal the following month, while 58 % remained low. Using the mean 3-month bicarbonate, only 29 % of high values remained high in the next 3-month period. In multivariable-adjusted longitudinal models, both low and high serum bicarbonate values were associated with greater variability than were normal values (β = 0.12 (95 % CI 0.09-0.15) and 0.24 (0.18 to 0.29) respectively). Variability decreased with time, and was significantly associated with age, phosphate binder use, serum creatinine, potassium, and normalized protein catabolic rate. CONCLUSIONS Monthly pre-dialysis serum bicarbonate levels are highly variable. Even if a clinician takes no action, approximately 50 % of bicarbonate values outside a normal range of 22-26 mEq/L will return to normal in the subsequent month. The decision to change the bicarbonate dialysis prescription should not be based on a single bicarbonate value, and even a 3-month mean may be insufficient.
منابع مشابه
The Effect of the Type of Hemodialysis Buffer on the QTc Interval in Patients on Chronic Hemodialysis
Background: Identifying the sources of variation in QTc measurements is important for preventing arrhythmias during and after hemodialysis. The present study was designed to determine the correlation between the type of hemodialysis buffer and the changes in QTc interval in patients on chronic hemodialysis. Methods: Fifty-nine patients on chronic hemodialysis who referred in winter 2007 to hemo...
متن کاملDialysis modality and correction of uremic metabolic acidosis: relationship with all-cause and cause-specific mortality.
BACKGROUND AND OBJECTIVES Uremic metabolic acidosis is only partially corrected in many hemodialysis patients, and low serum bicarbonate predicts higher death risk. This study determined the comparative efficacy of peritoneal dialysis in correcting uremic metabolic acidosis and the association of serum bicarbonate and death risk with the two therapies. DESIGN, SETTING, PARTICIPANTS, & MEASURE...
متن کاملComparision between effects of bicarbonate and acetate dialysates on spirometry parameters in patients with chronic renal failure undergoing hemodialysis
Introduction: Chronic renal failure causes impairment of all body organs including heart and lungs. Main problem in these patients are pulmonary edema due to increased permeability of capillaries, intravascular and interstitial volume overload, hypertension and heart failure. These changes cause altered physiologic and mechanical function of lungs. The objective of this study is evaluating the ...
متن کاملComparative Analysis of Serum Levels of Aluminum and Lead in Dialysis Patients, Pre and post Dialysis
Background: Accumulation or deficiency of trace elements can occur in hemodialysis patients and it increases risk of cardiovascular or other organs disorders. Special ions levels such as sodium and bicarbonate in dialysis fluid are accurately regulated but the remaining elements are not regularly measured. Aluminum and lead belong to the biologic performance free heavy metals .They also has a t...
متن کاملMonitoring of hemodialysis quality-of-care indicators: why is it important?
BACKGROUND Meeting specific guideline targets is associated with improved survival rates and reduced hospitalizations in the dialysis population. This prospective work evaluated the adequacy of hemodialysis quality indicators in an in-center hemodialysis population with severe comorbidities, and assessed whether clinical practice could impact intermediate outcomes. METHODS All the chronic hem...
متن کامل