Quantitative Analysis of Fundus-Image Sequences Reveals Phase of Spontaneous Venous Pulsations.

نویسندگان

  • Fabrice Moret
  • Charlotte M Reiff
  • Wolf A Lagrèze
  • Michael Bach
چکیده

PURPOSE Spontaneous venous pulsation correlates negatively with elevated intracranial pressure and papilledema, and it relates to glaucoma. Yet, its etiology remains unclear. A key element to elucidate its underlying mechanism is the time at which collapse occurs with respect to the heart cycle, but previous reports are contradictory. We assessed this question in healthy subjects using quantitative measurements of both vein diameters and artery lateral displacements; the latter being used as the marker of the ocular systole time. METHODS We recorded 5-second fundus sequences with a near-infrared scanning laser ophthalmoscope in 12 young healthy subjects. The image sequences were coregistered, cleaned from microsaccades, and filtered via a principal component analysis to remove nonpulsatile dynamic features. Time courses of arterial lateral displacement and of diameter at sites of spontaneous venous pulsation or proximal to the disk were retrieved from those image sequences and compared. RESULTS Four subjects displayed both arterial and venous pulsatile waveforms. On those, we observed venous diameter waveforms differing markedly among the subjects, ranging from a waveform matching the typical intraocular pressure waveform to a close replica of the arterial waveform. CONCLUSIONS The heterogeneity in waveforms and arteriovenous phases suggests that the mechanism governing the venous outflow resistance differs among healthy subjects. TRANSLATIONAL RELEVANCE Further characterizations are necessary to understand the heterogeneous mechanisms governing the venous outflow resistance as this resistance is altered in glaucoma and is instrumental when monitoring intracranial hypertension based on fundus observations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visualization of fundus vessel pulsation using principal component analysis.

PURPOSE Spontaneous venous pulsation is one of the clinical signs with which to rule out elevated intracranial pressure and papilledema. More subtle pulsatile retinal movements are difficult to observe because of eye movements. Recording a fundus movie and aligning (registering) the images helps, but the images still contain distracting microsaccadic distortions and noise. The authors hypothesi...

متن کامل

Improved quantification of salivary gland scintigraphy by means of factor analysis

Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...

متن کامل

Unilateral loss of spontaneous venous pulsations in an astronaut.

Spontaneous venous pulsations seen on the optic nerve head (optic disc) are presumed to be caused by fluctuations in the pressure gradient between the intraocular and retrolaminar venous systems. The disappearance of previously documented spontaneous venous pulsations is a well‐recognized clinical sign usually associated with a rise in intracranial pressure and a concomitant bilateral elevation...

متن کامل

Spontaneous retinal venous pulsation: aetiology and significance.

Spontaneous retinal venous pulsation is seen as a subtle variation in the calibre of the retinal vein(s) as they cross the optic disc. The physical principles behind the venous pulsations has been the point of much debate. Initial theories suggested that the pulsation occurred because of the rise in intraocular pressure in the eye with the pulse pressure. This article presents an argument that ...

متن کامل

Effect of isoproterenol, phenylephrine, and sodium nitroprusside on fundus pulsations in healthy volunteers.

AIMS/BACKGROUND Recently a laser interferometric method for topical measurement of fundus pulsations has been developed. Fundus pulsations in the macular region are caused by the inflow and outflow of blood into the choroid. The purpose of this work was to study the influence of a peripheral vasoconstricting (the alpha 1 adrenoceptor agonist phenylephrine), a predominantly positive inotropic (t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 2015