Reference-based MRI.
نویسندگان
چکیده
PURPOSE In many clinical MRI scenarios, existing imaging information can be used to significantly shorten acquisition time or to improve Signal to Noise Ratio (SNR). In this paper the authors present a framework, referred to as FASTMER, for fast MRI by exploiting a reference image. METHODS The proposed approach utilizes the possible similarity of the reference image to the acquired image, which exists in many clinical MRI imaging scenarios. Examples include similarity between adjacent slices in high resolution MRI, similarity between various contrasts in the same scan and similarity between different scans of the same patient. To account for the fact that the reference image may exhibit low similarity with the acquired image the authors develop an iterative weighted reconstruction approach, which tunes the weights according to the degree of similarity. RESULTS Experimental results demonstrate the performance of the method in three different clinical MRI scenarios: The first example demonstrates SNR improvement in high resolution brain MRI, the second scenario exploits similarity between T2-weighted and fluid-attenuated inversion recovery (FLAIR) for fast FLAIR scanning and the last application utilizes similarity between baseline and follow-up scans for fast follow-up acquisition. The results show that FASTMER outperforms image reconstruction of existing state-of-the-art methods. CONCLUSIONS The authors present a framework for fast MRI by exploiting a reference image. Recovery is based on an iterative algorithm that supports cases in which similarity to the reference scan is not guaranteed. This extends the applicability of the FASTMER to different MRI scanning scenarios. Thanks to the existence of reference images in various clinical imaging tasks, the proposed framework can play a major role in improving reconstruction in many MR applications.
منابع مشابه
Evaluation of Dose Distribution Accuracy in HDR Brachytherapy of Esophagus Cancer Based on MRI Normoxic Polymer Gel Dosimetry
Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...
متن کاملAccuracy of MRI in Comparison with Arthroscopic Findings in the Diagnosis of Anterior Cruciate Ligament and Meniscus Tears
Background: Magnetic resonance imaging (MRI) is of great aid in the diagnosis of knee lesions. Nevertheless, arthroscopy has remained the reference standard for the diagnosis of internal derangements of the knee, against which alternative diagnostic modalities should be compared. This study was designed to assess the value of MRI and clinical examination in the diagnosis of Anterior Cruciate Li...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کاملFDG-PET/MRI fused data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment
Background: To retrospectively describe imaging characteristics of liver metastases on fused FDG-PET/ MRI data sets and to compare the diagnostic accuracy of MRI and fused FDG-PET/MRI data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment. Materials and Methods: 43 oncological patients (mean age: 56+/- 11 years) were investigated by FDG-PET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 43 10 شماره
صفحات -
تاریخ انتشار 2016