Elastic and viscoelastic characterization of microcapsules for drug delivery using a force-feedback MEMS microgripper.
نویسندگان
چکیده
This paper reports a monolithic, force-feedback MEMS (microelectomechanical systems) microgripper and its application to micro-scale compression testing of swollen hydrogel microcapsules at wet state during manipulation. The single-chip microgripper integrates an electrothermal microactuator and two capacitive force sensors, one for contact detection (force resolution: 38.5 nN) and the other for gripping force measurements (force resolution: 19.9 nN). With the capability of resolving gripping forces down to 19.9 nN and material deformations with a 20.5 nm resolution, the system quantified Young's modulus values and viscoelastic parameters of alginate microcapsules (15-25 microm), demonstrating an easy-to-operate, accurate compression testing technique for characterizing soft, micrometer-sized biomaterials.
منابع مشابه
NanoNewton Force Sensing and Control in Microrobotic Cell Manipulation
Cellular force sensing and control techniques are capable of enhancing the dexterity and reliability of microrobotic cell manipulation systems. This paper presents a vision-based cellular force sensing technique using a microfabricated elastic cell holding device and a sub-pixel visual tracking algorithm for resolving forces down to 3.7nN during microrobotic mouse embryo injection. The techniqu...
متن کاملDevelopment and Characterization of Bioadhesive Gel of Microencapsulated Metronidazole for Vaginal Use
The present study concerned with the development and characterization of metronidazole microcapsules prepared by thermal change method using different ratios (1:1, 1:2 and 1:4) of ethyl cellulose in order to select the best microcapsule formulation with a good encapsulation efficiency and drug release profile. The obtained microcapsules were discrete, spherical with free flowing properties and ...
متن کاملDevelopment and Characterization of Bioadhesive Gel of Microencapsulated Metronidazole for Vaginal Use
The present study concerned with the development and characterization of metronidazole microcapsules prepared by thermal change method using different ratios (1:1, 1:2 and 1:4) of ethyl cellulose in order to select the best microcapsule formulation with a good encapsulation efficiency and drug release profile. The obtained microcapsules were discrete, spherical with free flowing properties and ...
متن کاملInvestigation of mechanical properties of soft hydrogel microcapsules in relation to protein delivery using a MEMS force sensor.
This article reports the investigation of mechanical properties of alginate-chitosan microcapsules and the relation to protein delivery. For microscale compression testing, a system based on a microelectromechanical systems (MEMS) capacitive force sensor was developed. The bulk microfabricated capacitive force sensors are capable of resolving forces up to 110 microN with a resolution of 33.2 nN...
متن کاملSimulation of a Microgripper with Electrothermal Actuator Using COMSOL Software Based on the Finite Element Method
Micro-electro-mechanical systems (MEMs) are Combination of electrical and mechanical components in Micron dimensions. In recent years, holding, actuating methods and handling of MEMs components such as microgripper, microsensors and etc. have been deeply studied. Microgrippers for handling, positioning and assembling of micro components are very useful so that for clamping need actuation create...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical microdevices
دوره 11 2 شماره
صفحات -
تاریخ انتشار 2009