Nsls In-vacuum Undulators and Mini-beta Straights

نویسندگان

  • G. Rakowsky
  • D. Lynch
چکیده

We review the work carried out in the X13 R&D Straight Section of the NSLS X-Ray Ring on small gap in-vacuum undulators (IVUNs). Then we discuss: (1) plans to replace the pure permanent magnet undulator in X13 by a hybrid design providing stronger magnetic fields, enhancing the tunability of the device; (2) plans to install hybrid IVUNs in the two RF straights of the X-Ray Ring, increasing the number of insertion devices in the XRay Ring to eight; (3) the possibility of reducing the vertical beta function in the X13 straight from 0.33 m down to 0.16 m. This reduction in beta function would allow us to decrease the usable undulator gap from 3mm down to 2mm, further increasing the tuning range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small-gap Undulator Experiment on the Nsls X-ray Ring"

We report results of an on-going experiment being carried out in the X13 straight section of the NSLS X-ray Ring which explores the limits of the operation of small-gap undulators. In particular, we discuss measurements of stored electron beam lifetime as a function of the vertical aperture presented by a 4-jaw scraper or a variable-aperture vacuum vessel. At an electron beam current of 300 mA ...

متن کامل

Mechanical Design of Nsls X-25 Small Gap Undulator

The mechanical design considerations are discussed with respect to the X-25 small gap in-vacuum hybrid permanent magnet and vanadium permendur undulator, currently under design at the NSLS. Performance predictions, mechanical, thermal and structural design methodology, both common to undulators of this type, and unique to the subject undulator, are discussed. The design requirements and mechani...

متن کامل

Initial results from an in-vacuum undulator in the NSLS X-ray ring.

A short-period in-vacuum undulator for the NSLS X-ray Ring has been developed in a collaboration between SPring-8 and the NSLS, and has achieved its project design goals during commissioning studies. The device is called IVUN (in-vacuum undulator) and employs magnet arrays (31 periods, with an 11 mm period) developed at SPring-8, while the requisite vacuum chamber and mechanical systems were de...

متن کامل

In-vacuum Undulators

The so-called in-vacuum undulators, in which magnet arrays are installed inside the vacuum chamber, have been proved to be a promising way toward shorter wavelength of synchrotron radiation (SR). Especially, it has been adopted in lots of medium-scale SR facilities to provide angstrom x rays to carry out protein-crystallography experiments. Needless to say, there have been a number of technical...

متن کامل

Macromolecular crystallography beamline X25 at the NSLS

Beamline X25 at the NSLS is one of the five beamlines dedicated to macromolecular crystallography operated by the Brookhaven National Laboratory Macromolecular Crystallography Research Resource group. This mini-gap insertion-device beamline has seen constant upgrades for the last seven years in order to achieve mini-beam capability down to 20 µm × 20 µm. All major components beginning with the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001