[Glucose oxidase as an analytic reagent].
نویسندگان
چکیده
Glucose oxidase (EC 1.1.3.4) is the most widely employed enzyme as analytical reagent. This is the result of (1) its utility in the determination of glucose, an analyte of wide analytical interest, and (2) its relatively low cost and good stability that make the glucose/glucose oxidase system a very convenient model for method development (particularly in the area of biosensors). This review discusses in detail enzyme structure, biocatalysis, enzymes as analytical reagents, properties of glucose oxidase (including a historical account), and the use of glucose oxidase as an analytical reagent in homogeneous systems as well as an immobilized reagent.
منابع مشابه
Detergent-containing glucose oxidase reagent for use with the Beckman glucose analyzer.
We describe a modified glucose oxidase reagent for use in the polarographic determination of glucose with the Beckman "Glucose Analyzer." The reagent contains 1 mL/L of a surfactant (Brij-35 250 g/L solution) as the wetting agent instead of glycerol. Precipitation of components associated with the formulation recommended by Fischl et al. [Clin. Chem. 21, 760 (1975)] does not occur with this rea...
متن کاملPreparation of a modified glucose oxidase reagent for the polarographic determinationof glucose with the Beckman "glucose analyzer".
In this modification, glucose oxidase, 140-180 U/ml, is dissolved in acetate buffer (pH 6):ethanol (96%):glycerol (80:10:10 by vol). Iodine and molybdate are used as catalysts, formaldehyde and mercuric iodide as preservatives, and octanol as an antifoaming agent. The reagent is suitable for use in the Beckman "Glucose Analyzer", it is stable at room temperature for at least six months, it is s...
متن کاملThe Estimation of Blood Galactose Using a Glucose Oxidase-catalase Reagent.
The removal of the blood glucose by yeast fermentation in a conventional blood galactose method is replaced by an enzymic reaction using a glucose oxidase-catalase reagent. The method can be readily modified to suit a variety of blood sugar estimation methods.
متن کاملThe coulometric determination of glucose in human serum.
The coulometric titration method is combined with the use of an enzymatic analytic reagent for the determination of glucose in human serum. The glucose in 25 ii. of serum is determined in a protein-free filtrate (PFF) with an accuracy of ± 3% and a coefficient of variation of approximately 2%. The procedure routinely covers a concentration range of 25-250 mg/100 ml. Calibrations are linear to a...
متن کاملAdaptation of Prostatic-Group-Label Homogeneous Immunoassay to reagent-strip format.
The Prostatic-Group-Label Immunoassay (PGLIA) technique has been incorporated into a reagent-strip format. We report use of flavin N6-(N'-2,4-dinitrophenyl-6-aminohexyl)adenine dinucleotide (DNP-FAD) as the prosthetic group derivative and 6-N-(2,4-dinitrophenyl)aminohexanoic acid (DNP-caproate) as the competing ligand. DNP-FAD not bound by antibody combines with glucose oxidase apoenzyme, which...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de fisiologia
دوره 13 4 شماره
صفحات -
تاریخ انتشار 1957