Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
نویسندگان
چکیده
The aim of this study is to compare the current state of lesion identification, the BI-RADS classification and the contrast-enhancement behavior at 7T and 3T breast MRI in the same patient group. Twenty-seven patients with thirty suspicious lesions were selected for this prospective study and underwent both 7T and 3T MRI. All examinations were rated by two radiologists (R1 and R2) independently on image quality, lesion identification and BI-RADS classification. We assessed sensitivity, specificity, NPV and PPV, observer agreement, lesion sizes, and contrast-enhancement-tonoise ratios (CENRs) of mass lesions. Fifteen of seventeen histopathological proven malignant lesions were detected at both field strengths. Image quality of the dynamic series was good at 7T, and excellent at 3T (P = 0.001 for R1 and P = 0.88 for R2). R1 found higher rates of specificity, NPV and PPV at 7T when compared to 3T, while R2 found the same results for sensitivity, specificity, NPV and PPV for both field strengths. The observers showed excellent agreement for BI-RADS categories at 7T (κ = 0.86) and 3T (κ = 0.93). CENRs were higher at 7T (P = 0.015). Lesion sizes were bigger at 7T according to R2 (P = 0.039). Our comparison study shows that 7T MRI allows BI-RADS conform analysis. Technical improvements, such as acquisition of T2w sequences and adjustment of B1+ field inhomogeneity, are still necessary to allow clinical use of 7T breast MRI.
منابع مشابه
Erratum to: Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study
[This corrects the article DOI: 10.1186/s40064-015-1654-7.].
متن کاملClinical Multiparametric MR Imaging of Breast Tumors at 7 Tesla
Magnetic Resonance Imaging (MRI) of the breast is a powerful imaging tool for the characterization, diagnosis, staging, and treatment monitoring of breast cancer. Applications at clinical magnetic field strengths (≤ 3T) have been extensively described. At 7T*, substantial improvements in image quality could be provided, if technical challenges can be overcome. In this article, the authors discu...
متن کامل1H MR Spectroscopy of the breast cancer at 3.0-Tesla: Comparison between pre- and post- contrast administration
Introduction Proton (1H) MR Spectroscopy (MRS) of the breast cancer has been reported to be useful for the diagnosis and the assessment of treatment response to chemotherapy (1). In most reports, MRS was obtained after dynamic contrast-enhanced MRI, since voxel of interest (VOI) for MRS could be located easily referring to contrast-enhanced MRI. However there are some reports that MRS was affec...
متن کاملHigh resolution MR imaging and spectroscopy of the human breast at 7T using a focused field RF coil setup
Introduction Contrast enhanced breast MRI has clinical relevance in cancer diagnoses and treatment monitoring, however at a limited specificity. Functional MRI techniques, like diffusion MRI and MR spectroscopy will contribute to improved specificity but compromised in sensitivity due to low spatial resolution. At 1.5T or 3T the improve of spatial is hindered by low signal to noise ratios even ...
متن کاملBreast Diffusion-weighted Imaging at 3 and 7 Tesla: Comparison Study
PURPOSE: Diffusion weighted imaging is a potential method for the detection and characterization of breast cancer [1]. By measuring apparent diffusion coefficient (ADC) values, it is possible to probe the local cellular microstructure in breast tissue. This may be used to distinguish between malignant and benign lesions and to recognize early response in cancer therapy monitoring. High field MR...
متن کامل