High-sensitivity quantitative PCR platform.

نویسندگان

  • Fred J DeGraves
  • Dongya Gao
  • Bernhard Kaltenboeck
چکیده

Real-time PCR methods have become widely used within the past few years. However, real-time PCR is rarely used to study chronic diseases with low pathogen loads, presumably because of insufficient sensitivity. In this report, we developed an integrated nucleic acid isolation and real-time PCR platform that vastly improved the sensitivity of the quantitative detection of the intracellular bacterium, Chlamydia spp., by fluorescence resonance energy transfer real-time PCR. Determinants of the overall detection sensitivity were analyzed by extracting nucleic acids from bovine milk specimens spiked with low amounts of chlamydial organisms. Nucleic acids were optimally preserved and recovered by collection in guanidinium stabilization buffer, binding to a matrix of glass fiber fleece, and elution in low volume. Step-down thermal cycling and an excess of hot-start Taq polymerase vastly improved the robustness and sensitivity of the real-time PCR while essentially maintaining 100% specificity. The amplification of Chlamydia 23S rRNA allowed for the differentiation of chlamydial species and was more robust at low target numbers than amplification of the omp1 gene. The best combined method detected single targets per a 100-microL specimen equivalent in a 5-microL real-time PCR input. In an initial application, this high-sensitivity real-time PCR platform demonstrated a high prevalence of chlamydial infection in cattle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IgG-detection devices for the Tus-Ter-lock immuno-PCR diagnostic platform.

The number of new Immuno-PCR technologies and applications is steadily growing as a result of a general need for more sensitive immunoassays for early detection of diseases. Although Immuno-PCR has been demonstrated to be superior to its immunoassay counterpart, it is still regarded as a challenging technology due to various problems arising from its increased detection power, such as high back...

متن کامل

Focused microarray analysis.

We describe detailed protocols and results with an integrated platform for studying relative transcript expression, including microarray design and fabrication, analysis and calibration algorithms, and high throughput quantitative real-time PCR. This approach optimizes sensitivity and accuracy while controlling the cost of experiments. A high quality cDNA array was fabricated using a restricted...

متن کامل

Development of qRT-PCR Test for Quantification of Rubella Virus in Commercially Available Vaccines

vaccines is considered as a critical point and in-process of quality control (IPQC) test of vaccine production. Rapid tests, like real time PCR, are more appropriated when the production occurs at industrial scale because of the amounts of starting materials and the excess of consumed time required. In the current study, a real-time quantitative reverse transcription-polymerase chain reaction...

متن کامل

Do-it-yourself: construction of a custom cDNA macroarray platform with high sensitivity and linear range

BACKGROUND Research involving gene expression profiling and clinical applications, such as diagnostics and prognostics, often require a DNA array platform that is flexibly customisable and cost-effective, but at the same time is highly sensitive and capable of accurately and reproducibly quantifying the transcriptional expression of a vast number of genes over the whole transcriptome dynamic ra...

متن کامل

Improving sample quality for target enrichment and next-gen sequencing with the Agilent High Sensitivity DNA Kit and the Agilent SureSelect Target Enrichment Platform

Next-generation sequencing (NGS) has revolutionized the genetic landscape. It is a lengthy, labor-intensive process that yields results never before achieved. As a result, it is imperative that the quality of the DNA sample be evaluated from the start, as most NGS sample preparation protocols require PCR amplification to generate DNA libraries prior to sequencing. The likelihood of artifact gen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2003