In vivo time-harmonic multifrequency elastography of the human liver.

نویسندگان

  • Heiko Tzschätzsch
  • Selcan Ipek-Ugay
  • Jing Guo
  • Kaspar-Josche Streitberger
  • Enno Gentz
  • Thomas Fischer
  • Robert Klaua
  • Michael Schultz
  • Jürgen Braun
  • Ingolf Sack
چکیده

Elastography is capable of noninvasively detecting hepatic fibrosis by imposing mechanical stress and measuring the viscoelastic response in the liver. Magnetic resonance elastography (MRE) relies on time-harmonic vibrations, while most dynamic ultrasound elastography methods employ transient stimulation methods. This study attempts to benefit from the advantages of time-harmonic tissue stimulation, i.e. relative insensitivity to obesity and ascites and mechanical approachability of the entire liver, and the advantages of ultrasound, i.e. time efficiency, low costs, and wide availability, by introducing in vivo time-harmonic elastography (THE) of the human liver using ultrasound and a broad range of harmonic stimulation frequencies. THE employs continuous harmonic shear vibrations at 7 frequencies from 30 to 60 Hz in a single examination and determines the elasticity and the viscosity of the liver from the dispersion of the shear wave speed within the applied frequency range. The feasibility of the method is demonstrated in the livers of eight healthy volunteers and a patient with cirrhosis. Multifrequency MRE at the same drive frequencies was used as elastographic reference method. Similar values of shear modulus and shear viscosity according the Kelvin-Voigt model were obtained by MRE and THE, indicating that the new method is suitable for in vivo quantification of the shear viscoelastic properties of the liver, however, in real-time and at a fraction of the costs of MRE. In conclusion, THE may provide a useful tool for fast assessment of the viscoelastic properties of the liver at low costs and without limitations in obesity, ascites or hemochromatosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Viscoelastic properties of liver measured by oscillatory rheometry and multifrequency magnetic resonance elastography.

The mechanical properties of liver can sensitively indicate the progression of hepatic fibrosis. Mechanical tissue characterization involves the analysis of the complex shear modulus measured either by oscillatory rheometry or by in vivo elastography. In this study, bovine liver specimens were investigated by oscillatory rheometry and multifrequency magnetic resonance elastography (MRE) in a co...

متن کامل

Multifrequency inversion in magnetic resonance elastography.

Time-harmonic shear wave elastography is capable of measuring viscoelastic parameters in living tissue. However, finite tissue boundaries and waveguide effects give rise to wave interferences which are not accounted for by standard elasticity reconstruction methods. Furthermore, the viscoelasticity of tissue causes dispersion of the complex shear modulus, rendering the recovered moduli frequenc...

متن کامل

In vivo wideband multifrequency MR elastography of the human brain and liver.

PURPOSE To demonstrate the feasibility of in vivo wideband MR elastography (wMRE) using continuous, time-harmonic shear vibrations in the frequency range of 10-50 Hz. THEORY AND METHODS The method was tested in a gel phantom with marked mechanical loss. The brains and livers of eight volunteers were scanned by wMRE using multislice, single-shot MRE with optimized fractional encoding and synch...

متن کامل

In vivo MR elastography of liver: Comparison to oscillatory rheometer studies of tissue specimen

Introduction: Magnetic Resonance Elastography (MRE) is capable to measure the mechanical properties of living tissue by externally introduced shear vibrations and phase contrast MRI [1]. In multifrequency MRE the complex shear modulus G*(ω) of biological tissue is measured at various mechanical vibration frequencies simultaneously. Viscoelastic tissue parameters can then be calculated by fittin...

متن کامل

In Vivo Abdominal Magnetic Resonance Elastography for the Assessment of Portal Hypertension Before and After Transjugular Intrahepatic Portosystemic Shunt Implantation: Erratum.

OBJECTIVE The objective of this study was to investigate the correlation between hepatic venous pressure gradient (HVPG) and in vivo viscoelasticity of the liver and spleen before and after transjugular intrahepatic portosystemic shunt (TIPS) implantation. MATERIALS AND METHODS Ten patients with portal hypertension were examined twice by 3-dimensional multifrequency magnetic resonance elastog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 59 7  شماره 

صفحات  -

تاریخ انتشار 2014